» Articles » PMID: 33659082

Highly Flexible Fiber Delivery of a High Peak Power Nanosecond Nd:YAG Laser Beam for Flexiscopic Applications

Overview
Specialty Radiology
Date 2021 Mar 4
PMID 33659082
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Minimally invasive laser surgeries that require the use of a flexible endoscope (flexiscope) could benefit from high-energy nanosecond laser pulses delivered through fibers for real-time tissue characterization and phenotyping. The damage threshold of the fiber's glass material limits the maximum amount of deliverable peak power. To transmit high-energy pulses without damaging the fiber material, large-diameter fibers are typically used, leading to a limited bending radius. Moreover, in a large-core fiber, self-focusing can damage the fiber even if the tip remains intact. In this work, we tested a fused-end fiber bundle combined with a beam shaper capable of delivering more than 20 MW (>100 mJ/5 ns). The fiber bundle was tested over more than eight hours of operation, with different bending radiuses down to 15 mm. The results demonstrate, to the best of our knowledge, the highest peak power delivered through a flexible fiber, for a frequency-doubled Q-switched Nd:YAG laser.

Citing Articles

Chip-scale high-peak-power semiconductor/solid-state vertically integrated laser.

Yue J, Tanaka K, Hirano G, Yonezawa G, Shimizu M, Iwakoshi Y Nat Commun. 2022; 13(1):5774.

PMID: 36182934 PMC: 9526722. DOI: 10.1038/s41467-022-33528-x.

References
1.
Xia W, Piras D, Singh M, van Hespen J, van Leeuwen T, Steenbergen W . Design and evaluation of a laboratory prototype system for 3D photoacoustic full breast tomography. Biomed Opt Express. 2013; 4(11):2555-69. PMC: 3829550. DOI: 10.1364/BOE.4.002555. View

2.
Sivasubramanian K, Periyasamy V, Wen K, Pramanik M . Optimizing light delivery through fiber bundle in photoacoustic imaging with clinical ultrasound system: Monte Carlo simulation and experimental validation. J Biomed Opt. 2016; 22(4):41008. DOI: 10.1117/1.JBO.22.4.041008. View

3.
Razansky D, Buehler A, Ntziachristos V . Volumetric real-time multispectral optoacoustic tomography of biomarkers. Nat Protoc. 2011; 6(8):1121-9. DOI: 10.1038/nprot.2011.351. View

4.
Bahreini M, Ashrafkhani B, Tavassoli S . Discrimination of patients with diabetes mellitus and healthy subjects based on laser-induced breakdown spectroscopy of their fingernails. J Biomed Opt. 2013; 18(10):107006. DOI: 10.1117/1.JBO.18.10.107006. View

5.
Matsuura Y, Tsuchiuchi A, Noguchi H, Miyagi M . Hollow fiber optics with improved durability for high-peak-power pulses of Q-switched Nd:YAG lasers. Appl Opt. 2007; 46(8):1279-82. DOI: 10.1364/ao.46.001279. View