» Articles » PMID: 33626450

The Modified Shriners Hospitals for Children Greenville (mSHCG) Multi-segment Foot Model Provides Clinically Acceptable Measurements of Ankle and Midfoot Angles: A Dual Fluoroscopy Study

Overview
Journal Gait Posture
Specialty Orthopedics
Date 2021 Feb 24
PMID 33626450
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Several multi-segment foot models have been developed to evaluate foot and ankle motion using skin-marker motion analysis. However, few multi-segment models have been evaluated against a reference standard to establish kinematic accuracy.

Research Question: How accurately do skin-markers estimate foot and ankle motion for the modified Shriners Hospitals for Children Greenville (mSHCG) multi-segment foot model when compared against the reference standard, dual fluoroscopy (DF), during gait, in asymptomatic participants?

Methods: Five participants walked overground as full-body skin-marker trajectory data and DF images of the foot and shank were simultaneously acquired. Using the mSHCG model, ankle and midfoot angles were calculated throughout stance for both motion analysis techniques. Statistical parametric mapping assessed differences in joint angles and marker positions between skin-marker and DF motion analysis techniques. Paired t tests, and linear regression models were used to compare joint angles and range of motion (ROM) calculated from the two techniques.

Results: In the coronal plane, the skin-marker model significantly overestimated ROM (p = 0.028). Further, the DF model midfoot ROM was significantly positively related to differences between DF and skin-marker midfoot angles (p = 0.035, adjusted R = 0.76). In the sagittal plane, skin-markers underestimated ankle angles by as much as 7.26°, while midfoot angles were overestimated by as much as 9.01°. However, DF and skin-marker joint angles were not significantly different over stance. Skin-markers on the tibia, calcaneus, and fifth metatarsal had significantly different positions than the DF markers along the direction of walking for isolated portions that were less than 10 % of stance. Euclidean distances between DF and skin-markers positions were less than 9.36 mm.

Significance: As the accuracy of the mSHCG model was formerly unknown, the results of this study provide ranges of confidence for key angles calculated by this model.

Citing Articles

Comparison of Foot Kinematics Between Normal Arch and Flexible Flatfoot Using the Oxford Foot Model: A Matched Case-Control Study.

Vijittrakarnrung C, Mongkolpichayaruk A, Limroongreungrat W, Chuckpaiwong B Foot Ankle Orthop. 2024; 9(1):24730114241231245.

PMID: 38410138 PMC: 10896060. DOI: 10.1177/24730114241231245.


Effect of lace-up ankle brace on the tibiotalar and subtalar joint during the landing.

Luo Y, Hu M, Li Z, Huang X, Wu D, Li F Front Bioeng Biotechnol. 2023; 11:1255944.

PMID: 37901843 PMC: 10602646. DOI: 10.3389/fbioe.2023.1255944.


Effects of fatigue on the kinematics and kinetics of talocrural and subtalar joint during landing.

Luo Y, Li Z, Hu M, Zhang L, Li F, Wang S Front Bioeng Biotechnol. 2023; 11:1252044.

PMID: 37829568 PMC: 10566632. DOI: 10.3389/fbioe.2023.1252044.


Effects of different habitual foot strike patterns on kinematics of the first metatarsophalangeal joint during shod running-a statistical parametric mapping study.

Wu K, Sun X, Ye D, Zhang F, Zhang S, Fu W Front Bioeng Biotechnol. 2023; 11:1251324.

PMID: 37744258 PMC: 10511762. DOI: 10.3389/fbioe.2023.1251324.


Present and future of gait assessment in clinical practice: Towards the application of novel trends and technologies.

Hulleck A, Mohan D, Abdallah N, El Rich M, Khalaf K Front Med Technol. 2023; 4:901331.

PMID: 36590154 PMC: 9800936. DOI: 10.3389/fmedt.2022.901331.


References
1.
Tranberg R, Karlsson D . The relative skin movement of the foot: a 2-D roentgen photogrammetry study. Clin Biomech (Bristol). 2001; 13(1):71-76. DOI: 10.1016/s0268-0033(97)00052-1. View

2.
Nester C, Liu A, Ward E, Howard D, Cocheba J, Derrick T . In vitro study of foot kinematics using a dynamic walking cadaver model. J Biomech. 2006; 40(9):1927-37. DOI: 10.1016/j.jbiomech.2006.09.008. View

3.
Long J, Eastwood D, Graf A, Smith P, Harris G . Repeatability and sources of variability in multi-center assessment of segmental foot kinematics in normal adults. Gait Posture. 2009; 31(1):32-6. DOI: 10.1016/j.gaitpost.2009.08.240. View

4.
Saraswat P, MacWilliams B, Davis R . A multi-segment foot model based on anatomically registered technical coordinate systems: method repeatability in pediatric feet. Gait Posture. 2011; 35(4):547-55. DOI: 10.1016/j.gaitpost.2011.11.022. View

5.
Carson M, Harrington M, Thompson N, OConnor J, Theologis T . Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis. J Biomech. 2001; 34(10):1299-307. DOI: 10.1016/s0021-9290(01)00101-4. View