» Articles » PMID: 33515663

The Effect of Heat-treatment on SARS-CoV-2 Viability and Detection

Overview
Journal J Virol Methods
Specialty Microbiology
Date 2021 Jan 30
PMID 33515663
Citations 28
Authors
Affiliations
Soon will be listed here.
Abstract

The development of safe diagnostic protocols for working with SARS-CoV-2 clinical samples at Biosafety Level 2 (BSL2) requires understanding of the effect of heat-treatment on SARS-CoV-2 viability and downstream RT-PCR sensitivity. In this study heating SARS-CoV-2/England/2/2020 to 56 °C and 60 °C for 15, 30 and 60 min reduced the virus titre by between 2.1 and 4.9 log pfu/mL (as determined by plaque assay). Complete inactivation did not occur and there was significant variability between replicates. Viable virus was detected by plaque assay after heat-treatment at 80 °C for 15 or 30 min but not 60 or 90 min. After heat-treatment at 80 °C for 60 min infectious virus was only detected by more sensitive virus culture. No viable virus was detected after heating to 80 °C for 90 min or 95 °C for 1 or 5 min. RT-PCR sensitivity was not compromised by heating to 56 °C and 60 °C. However, RT-PCR sensitivity was reduced (≥3 Ct value increase) after heating the virus to 80 °C for 30 min or longer, or 95 °C for 1 or 5 min. In summary we found that the efficacy of heat-inactivation varies greatly depending on temperature and duration. Local validation of heat-inactivation and its effects downstream is therefore essential for molecular testing.

Citing Articles

Detection of influenza virus in urban wastewater during the season 2022/2023 in Sicily, Italy.

Maida C, Mazzucco W, Priano W, Palermo R, Graziano G, Costantino C Front Public Health. 2024; 12:1383536.

PMID: 39109154 PMC: 11302137. DOI: 10.3389/fpubh.2024.1383536.


Validating the inactivation of viral pathogens with a focus on SARS-CoV-2 to safely transfer samples from high-containment laboratories.

Chaki S, Kahl-Mcdonagh M, Neuman B, Zuelke K Front Cell Infect Microbiol. 2024; 14:1292467.

PMID: 38510962 PMC: 10951993. DOI: 10.3389/fcimb.2024.1292467.


Optimization of the STARlet workflow for semi-automatic SARS-CoV-2 screening of swabs and deep respiratory materials using the RealAccurate Quadruplex SARS-CoV-2 PCR kit and Allplex SARS-CoV-2 PCR kit.

Flipse J, Tromp A, Thijssen D, van Xanten-Jans-Beken N, Pauwelsen R, van der Veer H Microbiol Spectr. 2024; 12(2):e0329623.

PMID: 38193688 PMC: 10846099. DOI: 10.1128/spectrum.03296-23.


Effect of nanosecond pulsed electric fields (nsPEFs) on coronavirus survival.

Cantu J, Barnes R, Gamboa B, Keister A, Echchgadda I, Ibey B AMB Express. 2023; 13(1):95.

PMID: 37689615 PMC: 10492771. DOI: 10.1186/s13568-023-01601-3.


Inactivated and Immunogenic SARS-CoV-2 for Safe Use in Immunoassays and as an Immunization Control for Non-Clinical Trials.

Gomes M, Linhares J, Dos Santos T, Pereira R, Santos R, da Silva S Viruses. 2023; 15(7).

PMID: 37515173 PMC: 10386713. DOI: 10.3390/v15071486.