» Articles » PMID: 33476012

Experimental Protocols for MRI Mapping of Renal T

Overview
Specialty Molecular Biology
Date 2021 Jan 21
PMID 33476012
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

The water proton longitudinal relaxation time, T, is a common and useful MR parameter in nephrology research. Here we provide three step-by-step T-mapping protocols suitable for different types of nephrology research. Firstly, we provide a single-slice 2D saturation recovery protocol suitable for studies of global pathology, where whole-kidney coverage is unnecessary. Secondly, we provide an inversion recovery type imaging protocol that may be optimized for specific kidney disease applications. Finally, we also provide imaging protocol for small animal kidney imaging in a clinical scanner.This chapter is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This analysis protocol chapter is complemented by two separate chapters describing the basic concept and experimental procedure.

Citing Articles

Optimization of Fair Arterial Spin Labeling Magnetic Resonance Imaging (ASL-MRI) for Renal Perfusion Quantification in Dogs: Pilot Study.

Hillaert A, Sanmiguel Serpa L, Xu Y, Hesta M, Bogaert S, Vanderperren K Animals (Basel). 2024; 14(12).

PMID: 38929429 PMC: 11201026. DOI: 10.3390/ani14121810.

References
1.
Vautier J, Heilmann M, Walczak C, Mispelter J, Volk A . 2D and 3D radial multi-gradient-echo DCE MRI in murine tumor models with dynamic R*2-corrected R1 mapping. Magn Reson Med. 2010; 64(1):313-8. DOI: 10.1002/mrm.22396. View

2.
Chow K, Flewitt J, Green J, Pagano J, Friedrich M, Thompson R . Saturation recovery single-shot acquisition (SASHA) for myocardial T(1) mapping. Magn Reson Med. 2013; 71(6):2082-95. DOI: 10.1002/mrm.24878. View

3.
Stollberger R, Wach P . Imaging of the active B1 field in vivo. Magn Reson Med. 1996; 35(2):246-51. DOI: 10.1002/mrm.1910350217. View

4.
Marques J, Kober T, Krueger G, van der Zwaag W, Van de Moortele P, Gruetter R . MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field. Neuroimage. 2009; 49(2):1271-81. DOI: 10.1016/j.neuroimage.2009.10.002. View

5.
Korb J, Bryant R . Magnetic field dependence of proton spin-lattice relaxation times. Magn Reson Med. 2002; 48(1):21-6. DOI: 10.1002/mrm.10185. View