» Articles » PMID: 33453463

Fully Integrated Microfluidic Devices for Qualitative, Quantitative and Digital Nucleic Acids Testing at Point of Care

Overview
Date 2021 Jan 16
PMID 33453463
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

Benefiting from emerging miniaturized and equipment-free nucleic acid testing (NAT) technologies, fully integrated NAT devices at point of care (POC) with the capability of "sample-in-answer-out" are proceeding at a break-neck speed to eliminate complex operations and reduce the risk of contamination. Like the development of polymerase chain reaction (PCR) technology (the standard technique for NAT), the detection signal of fully integrated NAT devices has evolved from qualitative to quantitative and recently to digital readout, aiming at expanding their extensive applications through gradually improving detection sensitivity and accuracy. This review firstly introduces the existing commercial products, and then illustrates recent fully integrated microfluidic devices for NAT at POC from the aspect of detection signals (i.e., qualitative, quantitative and digital). Importantly, the key issues of existing commercial products and the main challenges between scientific research and product development are discussed. On this basis, we envision that the MARCHED (miniaturized, automatic, reagent-preloaded, commercializable, high-throughput, environment-independent and disposable) NAT devices are expected to be realized in the near future.

Citing Articles

Microfluidics for the biological analysis of atmospheric ice-nucleating particles: Perspectives and challenges.

Tarn M, Shaw K, Foster P, West J, Johnston I, McCluskey D Biomicrofluidics. 2025; 19(1):011502.

PMID: 40041008 PMC: 11878220. DOI: 10.1063/5.0236911.


Microfluidics as a promising technology for personalized medicine.

Oushyani Roudsari Z, Esmaeili Z, Nasirzadeh N, Heidari Keshel S, Sefat F, Bakhtyari H Bioimpacts. 2025; 15:29944.

PMID: 39963565 PMC: 11830131. DOI: 10.34172/bi.29944.


Lab-on-a-Chip Devices for Nucleic Acid Analysis in Food Safety.

Lee I, Kim H Micromachines (Basel). 2025; 15(12.

PMID: 39770277 PMC: 11677256. DOI: 10.3390/mi15121524.


A drop dispenser for simplifying on-farm detection of foodborne pathogens.

Ranjbaran M, Kaur S, Wang J, Raut B, Verma M PLoS One. 2024; 19(12):e0315444.

PMID: 39739646 PMC: 11687705. DOI: 10.1371/journal.pone.0315444.


Palm-Sized Lab-In-A-Magnetofluidic Tube Platform for Rapid and Sensitive Virus Detection.

Li Z, Zhang S, Zhang J, Avery L, Banach D, Zhao H Adv Sci (Weinh). 2024; 11(23):e2310066.

PMID: 38634211 PMC: 11187901. DOI: 10.1002/advs.202310066.


References
1.
Sun Y, Quyen T, Hung T, Chin W, Wolff A, Bang D . A lab-on-a-chip system with integrated sample preparation and loop-mediated isothermal amplification for rapid and quantitative detection of Salmonella spp. in food samples. Lab Chip. 2015; 15(8):1898-904. DOI: 10.1039/c4lc01459f. View

2.
Ding X, Yin K, Li Z, Lalla R, Ballesteros E, Sfeir M . Ultrasensitive and visual detection of SARS-CoV-2 using all-in-one dual CRISPR-Cas12a assay. Nat Commun. 2020; 11(1):4711. PMC: 7501862. DOI: 10.1038/s41467-020-18575-6. View

3.
Liu D, Jia S, Zhang H, Ma Y, Guan Z, Li J . Integrating Target-Responsive Hydrogel with Pressuremeter Readout Enables Simple, Sensitive, User-Friendly, Quantitative Point-of-Care Testing. ACS Appl Mater Interfaces. 2017; 9(27):22252-22258. DOI: 10.1021/acsami.7b05531. View

4.
Kumar S, Gallagher R, Bishop J, Kline E, Buser J, Lafleur L . Long-term dry storage of enzyme-based reagents for isothermal nucleic acid amplification in a porous matrix for use in point-of-care diagnostic devices. Analyst. 2020; 145(21):6875-6886. PMC: 10335280. DOI: 10.1039/d0an01098g. View

5.
Kadimisetty K, Song J, Doto A, Hwang Y, Peng J, Mauk M . Fully 3D printed integrated reactor array for point-of-care molecular diagnostics. Biosens Bioelectron. 2018; 109:156-163. PMC: 6172948. DOI: 10.1016/j.bios.2018.03.009. View