Accuracy of Fibula Reconstruction Using Patient-Specific Cad/Cam Plates: A Multicenter Study on 47 Patients
Overview
Authors
Affiliations
Objectives: This prospective study evaluated the accuracy of mandibular reconstruction using free fibular flaps (by comparing virtual plans to the three-dimensional postoperative results), and the extent of bone-to-bone contact after computer-assisted surgery.
Methods: We included 65 patients who underwent partial-continuity mandibular resections from February 2013 to January 2017, and evaluated virtual planning, surgical techniques, and accuracy.
Results: Forty-seven patients were analysed. A total of 112 fibular segments received 54 implants. We measured 227 distances between landmarks to assess the accuracy of reconstruction. Postoperative reconstruction accuracy ranged from 0.5 to 3 mm.
Conclusion: Virtual surgical planning very accurately translated simulation into reality, particularly in patients requiring large, complex mandibular reconstructions using multiple fibular segments.
Level Of Evidence: 4 Laryngoscope, 131:E2169-E2175, 2021.
Kurosawa K, Ohkoshi A, Ishii R, Sato N, Miyashita H, Harata T JPRAS Open. 2024; 42:350-360.
PMID: 39583297 PMC: 11582545. DOI: 10.1016/j.jpra.2024.10.002.
Copelli C, Cacciatore F, Cocis S, Maglitto F, Barbara F, Iocca O Acta Otorhinolaryngol Ital. 2024; 44(Suppl. 1):S58-S66.
PMID: 38745517 PMC: 11098535. DOI: 10.14639/0392-100X-suppl.1-44-2024-N2819.
Liu R, Su Y, Pu J, Zhang C, Yang W Front Surg. 2023; 10:1132669.
PMID: 36969756 PMC: 10033664. DOI: 10.3389/fsurg.2023.1132669.
Bevini M, Vitali F, Ceccariglia F, Badiali G, Tarsitano A J Clin Med. 2023; 12(5).
PMID: 36902725 PMC: 10003983. DOI: 10.3390/jcm12051938.
Govoni F, Felici N, Ornelli M, Marcelli V, Migliano E, Pesucci B Maxillofac Plast Reconstr Surg. 2023; 45(1):6.
PMID: 36689098 PMC: 9871153. DOI: 10.1186/s40902-023-00374-w.