» Articles » PMID: 33420275

Breath Biopsy of Breast Cancer Using Sensor Array Signals and Machine Learning Analysis

Overview
Journal Sci Rep
Specialty Science
Date 2021 Jan 9
PMID 33420275
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Breast cancer causes metabolic alteration, and volatile metabolites in the breath of patients may be used to diagnose breast cancer. The objective of this study was to develop a new breath test for breast cancer by analyzing volatile metabolites in the exhaled breath. We collected alveolar air from breast cancer patients and non-cancer controls and analyzed the volatile metabolites with an electronic nose composed of 32 carbon nanotubes sensors. We used machine learning techniques to build prediction models for breast cancer and its molecular phenotyping. Between July 2016 and June 2018, we enrolled a total of 899 subjects. Using the random forest model, the prediction accuracy of breast cancer in the test set was 91% (95% CI: 0.85-0.95), sensitivity was 86%, specificity was 97%, positive predictive value was 97%, negative predictive value was 97%, the area under the receiver operating curve was 0.99 (95% CI: 0.99-1.00), and the kappa value was 0.83. The leave-one-out cross-validated discrimination accuracy and reliability of molecular phenotyping of breast cancer were 88.5 ± 12.1% and 0.77 ± 0.23, respectively. Breath tests with electronic noses can be applied intraoperatively to discriminate breast cancer and molecular subtype and support the medical staff to choose the best therapeutic decision.

Citing Articles

Transparency and Representation in Clinical Research Utilizing Artificial Intelligence in Oncology: A Scoping Review.

DAmiano A, Cheunkarndee T, Azoba C, Chen K, Mak R, Perni S Cancer Med. 2025; 14(5):e70728.

PMID: 40059400 PMC: 11891267. DOI: 10.1002/cam4.70728.


Development of Electronic Nose as a Complementary Screening Tool for Breath Testing in Colorectal Cancer.

Chen C, Zheng Y, Lin H, Yang H Biosensors (Basel). 2025; 15(2).

PMID: 39996984 PMC: 11852643. DOI: 10.3390/bios15020082.


Exploring Components, Sensors, and Techniques for Cancer Detection via eNose Technology: A Systematic Review.

Ramirez W, Pillajo V, Ramirez E, Manzano I, Meza D Sensors (Basel). 2024; 24(23).

PMID: 39686404 PMC: 11645018. DOI: 10.3390/s24237868.


The human volatilome meets cancer diagnostics: past, present, and future of noninvasive applications.

Barbosa J, Antoniosi Filho N Metabolomics. 2024; 20(5):113.

PMID: 39375265 DOI: 10.1007/s11306-024-02180-5.


Nose-on-Chip Nanobiosensors for Early Detection of Lung Cancer Breath Biomarkers.

Chaudhary V, Taha B, Lucky , Rustagi S, Khosla A, Papakonstantinou P ACS Sens. 2024; 9(9):4469-4494.

PMID: 39248694 PMC: 11443536. DOI: 10.1021/acssensors.4c01524.


References
1.
Wei Q, Dunbrack Jr R . The role of balanced training and testing data sets for binary classifiers in bioinformatics. PLoS One. 2013; 8(7):e67863. PMC: 3706434. DOI: 10.1371/journal.pone.0067863. View

2.
Buszewski B, Kesy M, Ligor T, Amann A . Human exhaled air analytics: biomarkers of diseases. Biomed Chromatogr. 2007; 21(6):553-66. DOI: 10.1002/bmc.835. View

3.
Phillips M, Cataneo R, Ditkoff B, Fisher P, Greenberg J, Gunawardena R . Prediction of breast cancer using volatile biomarkers in the breath. Breast Cancer Res Treat. 2006; 99(1):19-21. DOI: 10.1007/s10549-006-9176-1. View

4.
Saraoglu H, Edin B . E-Nose system for anesthetic dose level detection using artificial neural network. J Med Syst. 2007; 31(6):475-82. DOI: 10.1007/s10916-007-9087-7. View

5.
Peng G, Hakim M, Broza Y, Billan S, Abdah-Bortnyak R, Kuten A . Detection of lung, breast, colorectal, and prostate cancers from exhaled breath using a single array of nanosensors. Br J Cancer. 2010; 103(4):542-51. PMC: 2939793. DOI: 10.1038/sj.bjc.6605810. View