» Articles » PMID: 3339543

A Three-part System for Refining Intraocular Lens Power Calculations

Overview
Specialty Ophthalmology
Date 1988 Jan 1
PMID 3339543
Citations 149
Authors
Affiliations
Soon will be listed here.
Abstract

A three-part system that determines the correct power for an intraocular lens (IOL) to achieve a desired postoperative refraction is presented. The three components are (1) data screening criteria to identify improbable axial length and keratometry measurements, (2) a new IOL calculation formula that exceeds the current accuracy of other formulas for short, medium, and long eyes, and (3) a personalized "surgeon factor" that adjusts for any consistent bias in the surgeon's results, from any source, based on a reverse solution of the new formula; the reverse solution uses the postoperative stabilized refraction, the dioptric power of the implanted IOL, and the preoperative corneal and axial length measurements to calculate the personalized surgeon factor. The improved accuracy of the new formula was proven by performing IOL power calculations on 2,000 eyes from 12 surgeons and comparing the results to seven other currently used formulas.

Citing Articles

Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth.

Gao R, Zhang J, Han X, Huang Y, Huang R, Ye J BMC Ophthalmol. 2025; 25(1):21.

PMID: 39819497 PMC: 11737209. DOI: 10.1186/s12886-024-03793-z.


A New Intraocular Lens Power Formula Integrating an Artificial Intelligence-Powered Estimation for Effective Lens Position Based on Chinese Eyes.

Lou W, Zhou W, Wu M, Jin H Transl Vis Sci Technol. 2024; 13(10):40.

PMID: 39476087 PMC: 11534016. DOI: 10.1167/tvst.13.10.40.


[Basic aspects of IOL calculation].

Preussner P, Langenbucher A Ophthalmologie. 2024; 121(11):858-865.

PMID: 39446170 DOI: 10.1007/s00347-024-02129-y.


Accuracy assessment of artificial intelligence IOL calculation formulae: utilizing the heteroscedastic statistics and the Eyetemis Analysis Tool.

Reitblat O, Heifetz N, Durnford K, Pettey J, Olson R, Livny E Eye (Lond). 2024; 38(18):3578-3585.

PMID: 39322767 PMC: 11621322. DOI: 10.1038/s41433-024-03365-x.


A Multi Comparison of 8 Different Intraocular Lens Biometry Formulae, Including a Machine Learning Thin Lens Formula (MM) and an Inbuilt Anterior Segment Optical Coherence Tomography Ray Tracing Formula.

McNeely R, McGinnity K, Stewart S, Pazo E, Moutari S, Moore J Vision (Basel). 2024; 8(3).

PMID: 39311317 PMC: 11417848. DOI: 10.3390/vision8030049.