» Articles » PMID: 33394150

Modeling the Dynamic Kinetics of Microbial Disinfection with Dissipating Chemical Agents-a Theoretical Investigation

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

The most notable microbial survival models of disinfection kinetics are the original and modified versions of the static Chick-Watson-Hom's (CWH) initially developed for water chlorination. They can all be viewed as special cases of the Weibull survival model, where the observed static curve is the cumulative form (CDF) of the times at which the individual targeted microbes succumb to the treatment. The CWH model time's exponent is the distribution's shape factor, and its concentration-dependent rate parameter represents the distribution's scale factor's reciprocal. Theoretically, the concentration- dependence of the Weibull model's rate parameter need not to be always in a form of a power-law relationship as the CWH model requires, and two possible alternatives are presented. Apart from being chemically reactive, most chemical disinfectants are also volatile, and their effective concentration rarely remains constant. However, the published dynamic versions of the original CWH model are mathematically incongruent with their static versions. The issue is nonexistent in the dynamic version of the Weibull or other distribution-based models, provided that the momentary inactivation rate is expressed as the static rate at the momentary concentration, at the time that corresponds to the momentary survival ratio. The resulting model is an ordinary differential equation (ODE) whose numerical solution can describe survival curves under realistic regular and irregular disinfectant dissipation patterns, as well as during the disinfectant dispersion and/or its replenishment. KEY POINTS: • The Chick-Watson-Home models are treated as special cases of the Weibull distribution. • Dynamic microbial survival curve described as ordinary differential equation solution. • Survival rate models of disinfectant dissipation and replenishment patterns presented.

Citing Articles

Chemical Modification of Acrylonitrile-Divinylbenzene Polymer Supports with Aminophosphonate Groups and Their Antibacterial Activity Testing.

Nichita I, Lupa L, Visa A, Dragan E, Dinu M, Popa A Molecules. 2025; 29(24.

PMID: 39770142 PMC: 11677517. DOI: 10.3390/molecules29246054.


Heterogeneous survival upon disinfection underlies evolution of increased tolerance.

Nordholt N, Sobisch L, Godt A, Lewerenz D, Schreiber F Microbiol Spectr. 2024; :e0327622.

PMID: 39436131 PMC: 11619369. DOI: 10.1128/spectrum.03276-22.


MIUG BL21 paraprobiotics: Evidences on inactivation kinetics and their potential as cytocompatible and antitumor alternatives.

Stanciuc N, Borda D, Gurgu-Grigore L, Cotarlet M, Vasile A, Nistor O Food Chem X. 2024; 21:101114.

PMID: 38298354 PMC: 10828639. DOI: 10.1016/j.fochx.2024.101114.


Virus purification highlights the high susceptibility of SARS-CoV-2 to a chlorine-based disinfectant, chlorous acid.

Lawal-Ayinde B, Morita T, Oda K, Nazmul T, Kurose M, Nomura T PLoS One. 2023; 18(7):e0288634.

PMID: 37450488 PMC: 10348549. DOI: 10.1371/journal.pone.0288634.


Sensor setpoints that ensure compliance with microbial water quality targets for membrane bioreactor and chlorination treatment in on-site water reuse systems.

Reynaert E, Gretener F, Julian T, Morgenroth E Water Res X. 2023; 18:100164.

PMID: 37250292 PMC: 10214293. DOI: 10.1016/j.wroa.2022.100164.


References
1.
Schijven J, Teunis P, Suylen T, Ketelaars H, Hornstra L, Rutjes S . QMRA of adenovirus in drinking water at a drinking water treatment plant using UV and chlorine dioxide disinfection. Water Res. 2019; 158:34-45. DOI: 10.1016/j.watres.2019.03.090. View

2.
Armstrong A, Sobsey M, Casanova L . Disinfection of bacteriophage MS2 by copper in water. Appl Microbiol Biotechnol. 2017; 101(18):6891-6897. DOI: 10.1007/s00253-017-8419-x. View

3.
Ibarguen-Mondragon E, Revelo-Romo D, Hidalgo A, Garcia H, Galeano L . Mathematical modelling of MS2 virus inactivation by Al/Fe-PILC-activated catalytic wet peroxide oxidation (CWPO). Environ Sci Pollut Res Int. 2020; 27(16):19836-19844. DOI: 10.1007/s11356-020-08365-4. View

4.
CHICK H . An Investigation of the Laws of Disinfection. J Hyg (Lond). 2010; 8(1):92-158. PMC: 2167134. DOI: 10.1017/s0022172400006987. View

5.
Santoro D, Gehr R, Bartrand T, Liberti L, Notarnicola M, DellErba A . Wastewater disinfection by peracetic acid: assessment of models for tracking residual measurements and inactivation. Water Environ Res. 2007; 79(7):775-87. DOI: 10.2175/106143007x156817. View