Noninvasive Technique for Measuring Central Venous and Arterial Pressure Using Controlled Compression Sonography

Overview
Journal Ann Vasc Dis
Date 2021 Jan 4
PMID 33391557
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Devices that can noninvasively measure central and peripheral venous pressures with relative ease and in a short time were developed, but the resolution of the data that can be recorded with these devices is limited to 50 mmHg. We aimed to develop a system that could overcome this limitation. We used an innovative noninvasive controlled compression sonography device that could theoretically measure pressures higher than 200 mmHg. First, to validate the accuracy of our device, an in vitro study was conducted. Then, the values measured by our system were compared to conventionally obtained measurements of central venous, peripheral venous, and brachial artery pressures. Finally, regression analyses were used to determine the correlations between measurements obtained from different devices. With our device, the measurement of venous and arterial pressures required only 3 to 15 sec. All regression analyses revealed a significant statistical correlation between measurements, although the correlation coefficient was relatively low for arterial pressure. For venous pressure, our system can provide measurements that could not be measured noninvasively with conventional methods. Regarding arterial pressure, although our system could measure systolic pressure, further studies are needed to confirm the clinical efficacy of our device.

Citing Articles

Assessment of venous pressure by compression sonography of the internal jugular vein during 3 days of bed rest.

Hearon Jr C, Peters K, Dias K, MacNamara J, Marshall J, Campain J Exp Physiol. 2023; 108(12):1560-1568.

PMID: 37824038 PMC: 10988448. DOI: 10.1113/EP091372.

References
1.
Deol G, Collett N, Ashby A, Schmidt G . Ultrasound accurately reflects the jugular venous examination but underestimates central venous pressure. Chest. 2010; 139(1):95-100. DOI: 10.1378/chest.10-1301. View

2.
Xing C, Liu Y, Zhao M, Yang R, Duan Y, Zhang L . New method for noninvasive quantification of central venous pressure by ultrasound. Circ Cardiovasc Imaging. 2015; 8(5). DOI: 10.1161/CIRCIMAGING.114.003085. View

3.
Zimlichman E, Henderson D, Tamir O, Franz C, Song P, Yamin C . Health care-associated infections: a meta-analysis of costs and financial impact on the US health care system. JAMA Intern Med. 2013; 173(22):2039-46. DOI: 10.1001/jamainternmed.2013.9763. View

4.
Schanzer H, PEIRCE 2nd E . Pathophysiologic evaluation of chronic venous stasis with ambulatory venous pressure studies. Angiology. 1982; 33(3):183-91. DOI: 10.1177/000331978203300305. View

5.
Stergiou G, Alpert B, Mieke S, Asmar R, Atkins N, Eckert S . A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration.... Hypertension. 2018; 71(3):368-374. DOI: 10.1161/HYPERTENSIONAHA.117.10237. View