» Articles » PMID: 33389957

Time in Range from Continuous Glucose Monitoring: A Novel Metric for Glycemic Control

Overview
Specialty Endocrinology
Date 2021 Jan 4
PMID 33389957
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

Glycosylated hemoglobin (HbA1c) has been the sole surrogate marker for assessing diabetic complications. However, consistently reported limitations of HbA1c are that it lacks detailed information on short-term glycemic control and can be easily interfered with by various clinical conditions such as anemia, pregnancy, or liver disease. Thus, HbA1c alone may not represent the real glycemic status of a patient. The advancement of continuous glucose monitoring (CGM) has enabled both patients and healthcare providers to monitor glucose trends for a whole single day, which is not possible with HbA1c. This has allowed for the development of core metrics such as time spent in time in range (TIR), hyperglycemia, or hypoglycemia, and glycemic variability. Among the 10 core metrics, TIR is reported to represent overall glycemic control better than HbA1c alone. Moreover, various evidence supports TIR as a predictive marker of diabetes complications as well as HbA1c, as the inverse relationship between HbA1c and TIR reveals. However, there are more complex relationships between HbA1c, TIR, and other CGM metrics. This article provides information about 10 core metrics with particular focus on TIR and the relationships between the CGM metrics for comprehensive understanding of glycemic status using CGM.

Citing Articles

Quantification of the relation between continuous glucose monitoring observation period and the estimation error in assessing long-term glucose regulation.

Zoet S, Urgert T, Veldhuis A, van Beijnum B, Laverman G BMJ Open Diabetes Res Care. 2025; 13(1).

PMID: 40011057 PMC: 11865789. DOI: 10.1136/bmjdrc-2024-004768.


Improved Glycemic Control in Insulin-Treated Individuals With Poorly Controlled Type 2 Diabetes Through Combined Structured Education With Real-Time Continuous Glucose Monitoring.

Yoo J, Jun J, Kwak S, Kim J J Diabetes Sci Technol. 2025; :19322968241306136.

PMID: 39754348 PMC: 11699545. DOI: 10.1177/19322968241306136.


Impact of diverse aerobic exercise plans on glycemic control, lipid levels, and functional activity in stroke patients with type 2 diabetes mellitus.

Chen K, Wang Y, Li D, Li J, Huang Y, Huang M Front Endocrinol (Lausanne). 2024; 15:1389538.

PMID: 39359413 PMC: 11446103. DOI: 10.3389/fendo.2024.1389538.


Reinforcement Learning: A Paradigm Shift in Personalized Blood Glucose Management for Diabetes.

Denes-Fazakas L, Szilagyi L, Kovacs L, De Gaetano A, Eigner G Biomedicines. 2024; 12(9).

PMID: 39335656 PMC: 11429314. DOI: 10.3390/biomedicines12092143.


Two-week continuous glucose monitoring-derived metrics and degree of hepatic steatosis: a cross-sectional study among Chinese middle-aged and elderly participants.

Zhong H, Zhang K, Lin L, Yan Y, Shen L, Chen H Cardiovasc Diabetol. 2024; 23(1):322.

PMID: 39217368 PMC: 11366161. DOI: 10.1186/s12933-024-02409-6.


References
1.
Nathan D, Genuth S, Lachin J, Cleary P, Crofford O, Davis M . The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med. 1993; 329(14):977-86. DOI: 10.1056/NEJM199309303291401. View

2.
Sheng C, Tian J, Miao Y, Cheng Y, Yang Y, Reaven P . Prognostic Significance of Long-term HbA Variability for All-Cause Mortality in the ACCORD Trial. Diabetes Care. 2020; 43(6):1185-1190. DOI: 10.2337/dc19-2589. View

3.
Beck R, Bergenstal R, Riddlesworth T, Kollman C, Li Z, Brown A . Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials. Diabetes Care. 2018; 42(3):400-405. PMC: 6905478. DOI: 10.2337/dc18-1444. View

4.
Beck R, Bergenstal R, Cheng P, Kollman C, Carlson A, Johnson M . The Relationships Between Time in Range, Hyperglycemia Metrics, and HbA1c. J Diabetes Sci Technol. 2019; 13(4):614-626. PMC: 6610606. DOI: 10.1177/1932296818822496. View

5.
Vigersky R, McMahon C . The Relationship of Hemoglobin A1C to Time-in-Range in Patients with Diabetes. Diabetes Technol Ther. 2018; 21(2):81-85. DOI: 10.1089/dia.2018.0310. View