» Articles » PMID: 33361276

Recommendations for Determining the Validity of Consumer Wearable and Smartphone Step Count: Expert Statement and Checklist of the INTERLIVE Network

Abstract

Consumer wearable and smartphone devices provide an accessible means to objectively measure physical activity (PA) through step counts. With the increasing proliferation of this technology, consumers, practitioners and researchers are interested in leveraging these devices as a means to track and facilitate PA behavioural change. However, while the acceptance of these devices is increasing, the validity of many consumer devices have not been rigorously and transparently evaluated. The Towards Intelligent Health and Well-Being Network of Physical Activity Assessment (INTERLIVE) is a joint European initiative of six universities and one industrial partner. The consortium was founded in 2019 and strives to develop best-practice recommendations for evaluating the validity of consumer wearables and smartphones. This expert statement presents a best-practice consumer wearable and smartphone step counter validation protocol. A two-step process was used to aggregate data and form a scientific foundation for the development of an optimal and feasible validation protocol: (1) a systematic literature review and (2) additional searches of the wider literature pertaining to factors that may introduce bias during the validation of these devices. The systematic literature review process identified 2897 potential articles, with 85 articles deemed eligible for the final dataset. From the synthesised data, we identified a set of six key domains to be considered during design and reporting of validation studies: target population, criterion measure, index measure, validation conditions, data processing and statistical analysis. Based on these six domains, a set of key variables of interest were identified and a 'basic' and 'advanced' multistage protocol for the validation of consumer wearable and smartphone step counters was developed. The INTERLIVE consortium recommends that the proposed protocol is used when considering the validation of any consumer wearable or smartphone step counter. Checklists have been provided to guide validation protocol development and reporting. The network also provide guidance for future research activities, highlighting the imminent need for the development of feasible alternative 'gold-standard' criterion measures for free-living validation. Adherence to these validation and reporting standards will help ensure methodological and reporting consistency, facilitating comparison between consumer devices. Ultimately, this will ensure that as these devices are integrated into standard medical care, consumers, practitioners, industry and researchers can use this technology safely and to its full potential.

Citing Articles

Smartphone-based gait analysis in the assessment of fatigue and fatigability in people with multiple sclerosis: a supervised cohort study.

Schonherr C, Ziegler J, Zentek T, Rashid A, Strauss S, Tallner A J Neurol. 2025; 272(3):217.

PMID: 39985679 PMC: 11846754. DOI: 10.1007/s00415-025-12906-7.


Using Free-Living Heart Rate Data as an Objective Method to Assess Physical Activity: A Scoping Review and Recommendations by the INTERLIVE-Network Targeting Consumer Wearables.

Schumann M, Feuerbacher J, Heinrich L, Olvera-Rojas M, Sclafani A, Brond J Sports Med. 2025; .

PMID: 39893599 DOI: 10.1007/s40279-024-02159-1.


The wearable landscape: Issues pertaining to the validation of the measurement of 24-h physical activity, sedentary, and sleep behavior assessment.

Giurgiu M, von Haaren-Mack B, Fiedler J, Woll S, Burchartz A, Kolb S J Sport Health Sci. 2024; 14:101006.

PMID: 39491744 PMC: 11809201. DOI: 10.1016/j.jshs.2024.101006.


Validity and reliability of running gait measurement with the ViMove2 system.

Mason R, Barry G, Hall G, Godfrey A, Stuart S PLoS One. 2024; 19(10):e0312952.

PMID: 39480797 PMC: 11527157. DOI: 10.1371/journal.pone.0312952.


Integrating wearable devices into perioperative medicine: The potential, and future challenges.

Hunter A Future Healthc J. 2024; 11(3):100169.

PMID: 39253567 PMC: 11381431. DOI: 10.1016/j.fhj.2024.100169.


References
1.
Lee J, Williams S, Brown D, Laurson K . Concurrent validation of the Actigraph gt3x+, Polar Active accelerometer, Omron HJ-720 and Yamax Digiwalker SW-701 pedometer step counts in lab-based and free-living settings. J Sports Sci. 2014; 33(10):991-1000. DOI: 10.1080/02640414.2014.981848. View

2.
Hansen B, Dalene K, Ekelund U, Fagerland M, Kolle E, Steene-Johannessen J . Step by step: Association of device-measured daily steps with all-cause mortality-A prospective cohort Study. Scand J Med Sci Sports. 2020; 30(9):1705-1711. PMC: 7496562. DOI: 10.1111/sms.13726. View

3.
Asimina S, Chapizanis D, Karakitsios S, Kontoroupis P, Asimakopoulos D, Maggos T . Assessing and enhancing the utility of low-cost activity and location sensors for exposure studies. Environ Monit Assess. 2018; 190(3):155. DOI: 10.1007/s10661-018-6537-2. View

4.
Beltran-Carrillo V, Jimenez-Loaisa A, Alarcon-Lopez M, Elvira J . Validity of the "Samsung Health" application to measure steps: A study with two different samsung smartphones. J Sports Sci. 2018; 37(7):788-794. DOI: 10.1080/02640414.2018.1527199. View

5.
Lu M, Zhong W, Liu Y, Miao H, Li Y, Ji M . Sample Size for Assessing Agreement between Two Methods of Measurement by Bland-Altman Method. Int J Biostat. 2016; 12(2). DOI: 10.1515/ijb-2015-0039. View