Background: Implants made from bioabsorbable unsintered hydroxyapatite and poly-L-lactate composites (u-HA/PLLA) are widely used in the oral, maxillofacial, and orthopedic fields. This study assess the long-term (> 5 years) outcomes of patients with metacarpal fractures who were surgically treated using bioabsorbable plates and screws (Super-Fixsorb MX40 mesh; Teijin Medical Technology, Osaka, Japan).

Methods: A retrospective analysis of six patients with eight metacarpal fractures treated with bioabsorbable plates was done. All patients were followed for more than 5 years post-surgery. The clinical outcomes were evaluated using Q-DASH scores and the grip strength (GS): opposite side ratio. The resorption status of implants was assessed on plain computed tomography (CT) scans at final follow-up appointments.

Results: The mean age of the patients at the time of surgery was 29.5 years (16-54), and the median follow-up period was 81.8 months (68-101). All fractures united without displacement after an average of 3.5 months, and there were no implant specific complications associated with the use of absorbable plates. The mean grip strength ratio was 85.1% (56.8-104.5). The mean Q-DASH scores of 11.36 points (0-34.09) was good in all but two patients. We also observed that it took more than 8 years for the plates to be absorbed completely.

Conclusions: This study demonstrates that the process of bioabsorption in metacarpal fractures might be completed in about 8 years, and the absorption speeds were different inside and outside of the bone. The bioabsorbable plates are more cost-effective than metallic implants. The potential for bioabsorbable plates to be used in various clinical procedures is promising.

Citing Articles

Polylactic acid bioabsorbable implants of the hand: A review.

Jee E, Robichaux-Edwards L, Montgomery C, Bilderback K, Perry K, Massey P J Hand Microsurg. 2024; 16(3):100053.

PMID: 39035860 PMC: 11257132. DOI: 10.1016/j.jham.2024.100053.


Magnesium-Based Compression Screws in Acute Scaphoid Fractures and Nonunions.

Konneker S, Schachinger U, Vogt P World J Surg. 2023; 47(5):1129-1135.

PMID: 36774451 DOI: 10.1007/s00268-023-06937-2.


Long-Term Functional Results of Intra- and Extra-Articular Hand Fractures Treatment With Titanium Miniature Plates and Screws With Minimum Follow-Up of 24 Months.

Varitimidis S, Dailiana Z, Agorastakis D, Fyllos A, Zibis A, Hantes M Cureus. 2021; 13(6):e15438.

PMID: 34258109 PMC: 8255029. DOI: 10.7759/cureus.15438.

References
1.
Park C, Kim H, Lee J, Hong S, Ko Y, Lee O . Resorbable skeletal fixation systems for treating maxillofacial bone fractures. Arch Otolaryngol Head Neck Surg. 2011; 137(2):125-9. DOI: 10.1001/archoto.2010.241. View

2.
Dreyfuss D, Allon R, Izacson N, Hutt D . A Comparison of Locking Plates and Intramedullary Pinning for Fixation of Metacarpal Shaft Fractures. Hand (N Y). 2018; 14(1):27-33. PMC: 6346363. DOI: 10.1177/1558944718798854. View

3.
Singh V, Kshirsagar R, Halli R, Sane V, Chhabaria G, Ramanojam S . Evaluation of bioresorbable plates in condylar fracture fixation: a case series. Int J Oral Maxillofac Surg. 2013; 42(12):1503-5. DOI: 10.1016/j.ijom.2013.06.008. View

4.
Furukawa K, Sakai A, Menuki K, Oshige T, Zenke Y, Nakamura T . Post-traumatic malunion of the distal radial intra-articular fractures treated with autologous costal osteochondral grafts and bioabsorbable plates. Tech Hand Up Extrem Surg. 2013; 18(1):15-9. DOI: 10.1097/BTH.0000000000000020. View

5.
Christensen T, Samant S, Shin A . Making Sense of Metal Allergy and Hypersensitivity to Metallic Implants in Relation to Hand Surgery. J Hand Surg Am. 2017; 42(9):737-746. DOI: 10.1016/j.jhsa.2017.06.009. View