» Articles » PMID: 33059663

Four-corner Fusion Method Using a Bioabsorbable Plate for Scapholunate Advanced Collapse and Scaphoid Nonunion Advanced Collapse Wrists: a Case Series Study

Overview
Publisher Biomed Central
Specialties Orthopedics
Physiology
Date 2020 Oct 16
PMID 33059663
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Scaphoid excision and four-corner arthrodesis is an acceptable salvage procedure for the treatment of scapholunate advanced collapse (SLAC) and scaphoid nonunion advanced collapse (SNAC) wrists, since first popularized in the 1980s. We investigated the potential application of novel bioabsorbable plates and screws made of un-sintered hydroxyapatite/poly-L-lactide composite for the treatment of metacarpal fractures. We used this material for the fixation of four-corner fusions for SLAC or SNAC wrists commencing from April 2009. The purpose of this study was to clarify the controversy in the literature regarding the use of these plates.

Methods: The surgical procedures and clinical outcomes of four-corner fusions using a bioabsorbable (poly-L-lactic acid and hydroxyapatite) plate were reported. Ten patients (mean age, 59.2 years) with SLAC or SNAC wrists underwent fusions between April 2009 and June 2016. The primary diseases were scapholunate ligament injury, Preiser disease, and scaphoid pseudarthrosis. The mean postoperative follow-up period was 45.9 months (range, 12-86).

Results: In all patients, bone union was achieved without dislocation or pain. The mean wrist flexion and extension arc improved from 78.5 degrees before surgery to 90.5 degrees after surgery. Mean grip strength improved from 51 to 69% after surgery, and the Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) score improved from 53.5 to 14.3. No complications such as infection, avascular swelling, or tendon adhesion were observed. This implant requires no removal of internal fixation devices, produces stable outcomes, and is an effective fusion technique.

Conclusions: We summarized the outcomes of four-corner arthrodesis using bioabsorbable plates. Satisfactory clinical results were shown, with no obvious complications. This novel plate also serves as a good alternative for patients who are allergic to metals. Furthermore, bioabsorbable plates are advantageous as they do not require removal.

Citing Articles

Lunate-capitate arthrodesis for scaphoid nonunion: a comparative study.

Elshahhat A, Abed Y, Nour K BMC Musculoskelet Disord. 2024; 25(1):653.

PMID: 39164674 PMC: 11334583. DOI: 10.1186/s12891-024-07755-w.


Polylactic acid bioabsorbable implants of the hand: A review.

Jee E, Robichaux-Edwards L, Montgomery C, Bilderback K, Perry K, Massey P J Hand Microsurg. 2024; 16(3):100053.

PMID: 39035860 PMC: 11257132. DOI: 10.1016/j.jham.2024.100053.


Long-term outcomes of metacarpal fractures surgically treated using bioabsorbable plates: a retrospective study.

Kosugi K, Zenke Y, Tajima T, Yamanaka Y, Menuki K, Sakai A BMC Musculoskelet Disord. 2020; 21(1):817.

PMID: 33287779 PMC: 7722336. DOI: 10.1186/s12891-020-03841-x.

References
1.
Kendall C, Brown T, Millon S, Rudisill Jr L, Sanders J, Tanner S . Results of four-corner arthrodesis using dorsal circular plate fixation. J Hand Surg Am. 2005; 30(5):903-7. DOI: 10.1016/j.jhsa.2005.04.007. View

2.
Chung K, Watt A, Kotsis S . A prospective outcomes study of four-corner wrist arthrodesis using a circular limited wrist fusion plate for stage II scapholunate advanced collapse wrist deformity. Plast Reconstr Surg. 2006; 118(2):433-42. DOI: 10.1097/01.prs.0000227737.90007.5d. View

3.
Pauchard N, Lecoanet-Strugarek C, Segret J, De Gasperi M, Dap F, Dautel G . Dorsal locking plates versus staples in four-corner fusion: a comparative clinical and radiological study. Orthop Traumatol Surg Res. 2014; 100(6):593-7. DOI: 10.1016/j.otsr.2014.05.016. View

4.
van Amerongen E, Schuurman A . Four-corner arthrodesis using the Quad memory staple. J Hand Surg Eur Vol. 2009; 34(2):252-5. DOI: 10.1177/1753193408094444. View

5.
Kraisarin J, Dennison D, Berglund L, An K, Shin A . Biomechanical comparison of three fixation techniques used for four-corner arthrodesis. J Hand Surg Eur Vol. 2011; 36(7):560-7. DOI: 10.1177/1753193411406799. View