Update on Latest Advances in Time-of-flight PET

Overview
Journal Phys Med
Date 2020 Nov 19
PMID 33212421
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

This paper provides an update on time-of-flight (TOF) PET with a focus on latest hardware developments leading to current commercial PET/CT instruments. We describe advances in scintillator development, new photosensors and associated electronics readout, and detector designs for utilization in complete systems. Next, we introduce the latest commercial PET/CT scanners based on the aforementioned technologies, and discuss the detector design choices made that are relevant to differences in the system performance. Finally, we end with a discussion of the latest performance benchmarks for improved timing in PET detectors, challenges in scaling this performance to a complete system, and the outlook towards achieving a sub-50 ps coincidence timing resolution (CTR) in a PET detector.

Citing Articles

Recent Breakthroughs in PET-CT Multimodality Imaging: Innovations and Clinical Impact.

Hussain D, Abbas N, Khan J Bioengineering (Basel). 2025; 11(12.

PMID: 39768032 PMC: 11672880. DOI: 10.3390/bioengineering11121213.


Performance Characteristics of a New Generation 148-cm Axial Field-of-View uMI Panorama GS PET/CT System with Extended NEMA NU 2-2018 and EARL Standards.

Zhang H, Ren C, Liu Y, Yan X, Liu M, Hao Z J Nucl Med. 2024; 65(12):1974-1982.

PMID: 39510588 PMC: 11619581. DOI: 10.2967/jnumed.124.267963.


Study of modulation in complex refractive indices induced by ultrafast relativistic electrons using infrared and THz probe pulses.

Jeong D, Bark H, Kim Y, Shin J, Kim H, Oang K Phys Med Biol. 2024; 69(23).

PMID: 39419084 PMC: 11684476. DOI: 10.1088/1361-6560/ad8832.


Radiation Detectors and Sensors in Medical Imaging.

Michail C, Liaparinos P, Kalyvas N, Kandarakis I, Fountos G, Valais I Sensors (Basel). 2024; 24(19).

PMID: 39409289 PMC: 11478476. DOI: 10.3390/s24196251.


Artificial intelligence for response prediction and personalisation in radiation oncology.

Zwanenburg A, Price G, Lock S Strahlenther Onkol. 2024; 201(3):266-273.

PMID: 39212687 PMC: 11839704. DOI: 10.1007/s00066-024-02281-z.


References
1.
Chen S, Hu P, Gu Y, Yu H, Shi H . Performance characteristics of the digital uMI550 PET/CT system according to the NEMA NU2-2018 standard. EJNMMI Phys. 2020; 7(1):43. PMC: 7316913. DOI: 10.1186/s40658-020-00315-w. View

2.
Hsu D, Ilan E, Peterson W, Uribe J, Lubberink M, Levin C . Studies of a Next-Generation Silicon-Photomultiplier-Based Time-of-Flight PET/CT System. J Nucl Med. 2017; 58(9):1511-1518. DOI: 10.2967/jnumed.117.189514. View

3.
Moliner L, Gonzalez A, Soriano A, Sanchez F, Correcher C, Orero A . Design and evaluation of the MAMMI dedicated breast PET. Med Phys. 2012; 39(9):5393-404. DOI: 10.1118/1.4742850. View

4.
Gundacker S, Turtos R, Kratochwil N, Pots R, Paganoni M, Lecoq P . Experimental time resolution limits of modern SiPMs and TOF-PET detectors exploring different scintillators and Cherenkov emission. Phys Med Biol. 2019; 65(2):025001. DOI: 10.1088/1361-6560/ab63b4. View

5.
Lv Y, Lv X, Liu W, Judenhofer M, Zwingenberger A, Wisner E . Mini EXPLORER II: a prototype high-sensitivity PET/CT scanner for companion animal whole body and human brain scanning. Phys Med Biol. 2019; 64(7):075004. PMC: 6666419. DOI: 10.1088/1361-6560/aafc6c. View