» Articles » PMID: 33178954

Metal Artifact Correction Strategies in MRI-based Attenuation Correction in PET/MRI

Overview
Journal BJR Open
Specialty Radiology
Date 2020 Nov 12
PMID 33178954
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

In hybrid positron emission tomography (PET) and MRI systems, attenuation correction for PET image reconstruction is commonly based on processing of dedicated MR images. The image quality of the latter is strongly affected by metallic objects inside the body, such as . dental implants, endoprostheses, or surgical clips which all lead to substantial artifacts that propagate into MRI-based attenuation images. In this work, we review publications about metal artifact correction strategies in MRI-based attenuation correction in PET/MRI. Moreover, we also give an overview about publications investigating the impact of MRI-based attenuation correction metal artifacts on the reconstructed PET image quality and quantification.

Citing Articles

Deep learning applications for quantitative and qualitative PET in PET/MR: technical and clinical unmet needs.

Yang J, Afaq A, Sibley R, McMilan A, Pirasteh A MAGMA. 2024; 37(4):749-763.

PMID: 39167304 DOI: 10.1007/s10334-024-01199-y.


Application of PET/MRI in Gynecologic Malignancies.

Ebrahimi S, Lundstrom E, Batasin S, Hedlund E, Stalberg K, Ehman E Cancers (Basel). 2024; 16(8).

PMID: 38672560 PMC: 11048306. DOI: 10.3390/cancers16081478.


Artificial Intelligence-Driven Single-Shot PET Image Artifact Detection and Disentanglement: Toward Routine Clinical Image Quality Assurance.

Shiri I, Salimi Y, Hervier E, Pezzoni A, Sanaat A, Mostafaei S Clin Nucl Med. 2023; 48(12):1035-1046.

PMID: 37883015 PMC: 10662584. DOI: 10.1097/RLU.0000000000004912.


Reconstruction of Chronic, Retracted Pectoralis Major Tendon Tear With Achilles Tendon Allograft.

Rivera P, Dhytadak D, Cunningham G Arthrosc Tech. 2023; 12(4):e449-e452.

PMID: 37138694 PMC: 10149781. DOI: 10.1016/j.eats.2022.11.027.


Attenuation correction for PET/MRI to measure tracer activity surrounding total knee arthroplasty.

Bourdon C, Koudys Z, Lanting B, Appleton C, Thiessen J, Teeter M Eur J Hybrid Imaging. 2022; 6(1):31.

PMID: 36336748 PMC: 9637681. DOI: 10.1186/s41824-022-00152-3.


References
1.
Jang H, Liu F, Zhao G, Bradshaw T, McMillan A . Technical Note: Deep learning based MRAC using rapid ultrashort echo time imaging. Med Phys. 2018; . PMC: 6443501. DOI: 10.1002/mp.12964. View

2.
Fuin N, Pedemonte S, Catalano O, Izquierdo-Garcia D, Soricelli A, Salvatore M . PET/MRI in the Presence of Metal Implants: Completion of the Attenuation Map from PET Emission Data. J Nucl Med. 2017; 58(5):840-845. PMC: 5414501. DOI: 10.2967/jnumed.116.183343. View

3.
Schramm G, Langner J, Hofheinz F, Petr J, Beuthien-Baumann B, Platzek I . Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction. MAGMA. 2012; 26(1):115-26. PMC: 3572377. DOI: 10.1007/s10334-012-0328-5. View

4.
Koch K, Lorbiecki J, Hinks R, King K . A multispectral three-dimensional acquisition technique for imaging near metal implants. Magn Reson Med. 2009; 61(2):381-90. DOI: 10.1002/mrm.21856. View

5.
Nuyts J, Dupont P, Stroobants S, Benninck R, Mortelmans L, Suetens P . Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms. IEEE Trans Med Imaging. 1999; 18(5):393-403. DOI: 10.1109/42.774167. View