2-D Ultrasonic Array-Based Optical Coherence Elastography

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

Acoustic radiation force optical coherence elastography (ARF-OCE) has been successfully implemented to characterize the biomechanical properties of soft tissues, such as the cornea and the retina, with high resolution using single-element ultrasonic transducers for ARF excitation. Most currently proposed OCE techniques, such as air puff and ARF, have less capability to control the spatiotemporal information of the induced region of deformation, resulting in limited accuracy and low temporal resolution of the shear wave elasticity imaging. In this study, we propose a new method called 2-D ultrasonic array-based OCE imaging, which combines the advantages of 3-D dynamic electronic steering of the 2-D ultrasonic array and high-resolution optical coherence tomography (OCT). The 3-D steering capability of the 2-D array was first validated using a hydrophone. Then, the combined 2-D ultrasonic array OCE system was calibrated using a homogenous phantom, followed by an experiment on ex vivo rabbit corneal tissue. The results demonstrate that our newly developed 2-D ultrasonic array-based OCE system has the capability to map tissue biomechanical properties accurately, and therefore, has the potential to be a vital diagnostic tool in ophthalmology.

Citing Articles

Near-infrared spectroscopy-enabled electromechanical systems for fast mapping of biomechanics and subcutaneous diagnosis.

Wang Y, Henderson J, Hafiz P, Turlapati P, Ramsgard D, Lipman W Sci Adv. 2024; 10(46):eadq9358.

PMID: 39536095 PMC: 11559610. DOI: 10.1126/sciadv.adq9358.


corneal elastography: A topical review of challenges and opportunities.

Lan G, Twa M, Song C, Feng J, Huang Y, Xu J Comput Struct Biotechnol J. 2023; 21:2664-2687.

PMID: 37181662 PMC: 10173410. DOI: 10.1016/j.csbj.2023.04.009.


Biomechanical Measurements of the Cornea.

Li F, Wang K, Liu Z Bioengineering (Basel). 2023; 10(1).

PMID: 36671692 PMC: 9854753. DOI: 10.3390/bioengineering10010120.


2-D Array Design and Fabrication With Pitch-Shifting Interposer at Frequencies From 4 MHz up to 10 MHz.

Kang H, Sun Y, Wodnicki R, He Q, Zeng Y, Lu G IEEE Trans Ultrason Ferroelectr Freq Control. 2022; 69(12):3382-3391.

PMID: 36315528 PMC: 10353697. DOI: 10.1109/TUFFC.2022.3216602.


assessment of corneal biomechanics under a localized cross-linking treatment using confocal air-coupled optical coherence elastography.

Zvietcovich F, Nair A, Singh M, Aglyamov S, Twa M, Larin K Biomed Opt Express. 2022; 13(5):2644-2654.

PMID: 35774330 PMC: 9203097. DOI: 10.1364/BOE.456186.


References
1.
Lizzi F, Coleman D . History of ophthalmic ultrasound. J Ultrasound Med. 2004; 23(10):1255-66. DOI: 10.7863/jum.2004.23.10.1255. View

2.
Valbon B, Ambrosio Jr R, Fontes B, Luz A, Roberts C, Alves M . Ocular biomechanical metrics by CorVis ST in healthy Brazilian patients. J Refract Surg. 2014; 30(7):468-73. DOI: 10.3928/1081597X-20140521-01. View

3.
Luce D . Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005; 31(1):156-62. DOI: 10.1016/j.jcrs.2004.10.044. View

4.
Haw W, Manche E . Iatrogenic keratectasia after a deep primary keratotomy during laser in situ keratomileusis. Am J Ophthalmol. 2001; 132(6):920-1. DOI: 10.1016/s0002-9394(01)01148-5. View

5.
Bussel I, Wollstein G, Schuman J . OCT for glaucoma diagnosis, screening and detection of glaucoma progression. Br J Ophthalmol. 2013; 98 Suppl 2:ii15-9. PMC: 4208340. DOI: 10.1136/bjophthalmol-2013-304326. View