» Articles » PMID: 33083158

Upper-room Ultraviolet Air Disinfection Might Help to Reduce COVID-19 Transmission in Buildings: a Feasibility Study

Overview
Journal PeerJ
Date 2020 Oct 21
PMID 33083158
Citations 32
Authors
Affiliations
Soon will be listed here.
Abstract

As the world's economies come out of the lockdown imposed by the COVID-19 pandemic, there is an urgent need for technologies to mitigate COVID-19 transmission in confined spaces such as buildings. This feasibility study looks at one such technology, upper-room ultraviolet (UV) air disinfection, that can be safely used while humans are present in the room space, and which has already proven its efficacy as an intervention to inhibit the transmission of airborne diseases such as measles and tuberculosis. Using published data from various sources, it is shown that the SARS-CoV-2 virus, the causative agent of COVID-19, is highly likely to be susceptible to UV-C damage when suspended in air, with a UV susceptibility constant likely to be in the region 0.377-0.590 m/J, similar to that for other aerosolised coronaviruses. As such, the UV-C flux required to disinfect the virus is expected to be acceptable and safe for upper-room applications. Through analysis of expected and worst-case scenarios, the efficacy of the upper-room UV-C approach for reducing COVID-19 transmission in confined spaces (with moderate but sufficient ceiling height) is demonstrated. Furthermore, it is shown that with SARS-CoV-2, it should be possible to achieve high equivalent air change rates using upper-room UV air disinfection, suggesting that the technology might be particularly applicable to poorly ventilated spaces.

Citing Articles

End-to-end SARS-CoV-2 transmission risks in sport: Current evidence and practical recommendations.

Jones B, Phillips G, Valeriani F, Edwards T, Adams E, Bonadonna L S Afr J Sports Med. 2024; 33(1):v33i1a11210.

PMID: 39498368 PMC: 11534289. DOI: 10.17159/2078-516X/2021/v33i1a11210.


Creating respiratory pathogen-free environments in healthcare and nursing-care settings: a comprehensive review.

Nagy A, Czitrovszky A, Lehoczki A, Farkas A, Furi P, Osan J Geroscience. 2024; 47(1):543-571.

PMID: 39392557 PMC: 11872867. DOI: 10.1007/s11357-024-01379-7.


Estimation of the UV susceptibility of aerosolized SARS-CoV-2 to 254 nm irradiation using CFD-based room disinfection simulations.

van der Schans M, Yu J, de Vries A, Martin G Sci Rep. 2024; 14(1):15963.

PMID: 38987323 PMC: 11237116. DOI: 10.1038/s41598-024-63472-3.


Inactivation of Pathogens in Air Using Ultraviolet Direct Irradiation Below Exposure Limits.

Allen G, Benner K, Bahnfleth W J Res Natl Inst Stand Technol. 2024; 126:126052.

PMID: 38469440 PMC: 10046823. DOI: 10.6028/jres.126.052.


Identification of key potential infection processes and risk factors in the computed tomography examination process by FMEA method under COVID-19.

Jin L, Ye M, Lin W, Ye Y, Chuang Y, Luo J BMC Infect Dis. 2024; 24(1):257.

PMID: 38395803 PMC: 10893727. DOI: 10.1186/s12879-024-09136-z.


References
1.
Bedell K, Buchaklian A, Perlman S . Efficacy of an Automated Multiple Emitter Whole-Room Ultraviolet-C Disinfection System Against Coronaviruses MHV and MERS-CoV. Infect Control Hosp Epidemiol. 2016; 37(5):598-9. PMC: 5369231. DOI: 10.1017/ice.2015.348. View

2.
Biasin M, Bianco A, Pareschi G, Cavalleri A, Cavatorta C, Fenizia C . UV-C irradiation is highly effective in inactivating SARS-CoV-2 replication. Sci Rep. 2021; 11(1):6260. PMC: 7973506. DOI: 10.1038/s41598-021-85425-w. View

3.
McDevitt J, Milton D, Rudnick S, First M . Inactivation of poxviruses by upper-room UVC light in a simulated hospital room environment. PLoS One. 2008; 3(9):e3186. PMC: 2527528. DOI: 10.1371/journal.pone.0003186. View

4.
Keil S, Bowen R, Marschner S . Inactivation of Middle East respiratory syndrome coronavirus (MERS-CoV) in plasma products using a riboflavin-based and ultraviolet light-based photochemical treatment. Transfusion. 2016; 56(12):2948-2952. PMC: 7169765. DOI: 10.1111/trf.13860. View

5.
Cheng Y, Chen H, Sanchez Basurto L, Protasenko V, Bharadwaj S, Islam M . Inactivation of Listeria and E. coli by Deep-UV LED: effect of substrate conditions on inactivation kinetics. Sci Rep. 2020; 10(1):3411. PMC: 7042228. DOI: 10.1038/s41598-020-60459-8. View