» Articles » PMID: 33005604

Exploring Graphene and MoS Chips Based Surface Plasmon Resonance Biosensors for Diagnostic Applications

Overview
Journal Front Chem
Specialty Chemistry
Date 2020 Oct 2
PMID 33005604
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Until now, two-dimensional (2D) nanomaterials have been widely studied and applied in the biosensor field. Some of the advantages offered by these 2D materials include large specific surface area, high conductivity, and easy surface modification. This review discusses the use of 2D material in surface plasmon resonance (SPR) biosensor for diagnostic applications. Two-dimensional material reviewed includes graphene and molybdenum disulfide (MoS). The discussion begins with a brief introduction to the general principles of the SPR biosensor. The discussion continues by explaining the properties and characteristics of each material and its effect on the performance of the SPR biosensor, in particular its sensitivity. This review concludes with some recent applications of graphene- and MoS-based SPR biosensor in diagnostic applications.

Citing Articles

Reviewing advances in nanophotonic biosensors.

Javaid Z, Iqbal M, Javeed S, Maidin S, Morsy K, Shati A Front Chem. 2024; 12:1449161.

PMID: 39318420 PMC: 11420028. DOI: 10.3389/fchem.2024.1449161.


Microfluidic preparation of optical sensors for biomedical applications.

Wang Q, Wang C, Yang X, Wang J, Zhang Z, Shang L Smart Med. 2024; 2(1):e20220027.

PMID: 39188556 PMC: 11235902. DOI: 10.1002/SMMD.20220027.


The Tunable Parameters of Graphene-Based Biosensors.

Tene T, Svozilik J, Colcha D, Cevallos Y, Vinueza-Naranjo P, Vacacela Gomez C Sensors (Basel). 2024; 24(15).

PMID: 39124094 PMC: 11314989. DOI: 10.3390/s24155049.


Advances in Nanoplasmonic Biosensors: Optimizing Performance for Exosome Detection Applications.

Nurrohman D, Chiu N, Hsiao Y, Lai Y, Nanda H Biosensors (Basel). 2024; 14(6).

PMID: 38920611 PMC: 11201745. DOI: 10.3390/bios14060307.


Biosensing Platforms for Cardiac Biomarker Detection.

Gerdan Z, Saylan Y, Denizli A ACS Omega. 2024; 9(9):9946-9960.

PMID: 38463295 PMC: 10918812. DOI: 10.1021/acsomega.3c06571.


References
1.
Kim N, Choi M, Kim T, Choi W, Park S, Byun K . Sensitivity and Stability Enhancement of Surface Plasmon Resonance Biosensors based on a Large-Area Ag/MoS Substrate. Sensors (Basel). 2019; 19(8). PMC: 6514981. DOI: 10.3390/s19081894. View

2.
Rich R, Hoth L, Geoghegan K, Brown T, Lemotte P, Simons S . Kinetic analysis of estrogen receptor/ligand interactions. Proc Natl Acad Sci U S A. 2002; 99(13):8562-7. PMC: 124311. DOI: 10.1073/pnas.142288199. View

3.
Kaushik S, Tiwari U, Deep A, Sinha R . Two-dimensional transition metal dichalcogenides assisted biofunctionalized optical fiber SPR biosensor for efficient and rapid detection of bovine serum albumin. Sci Rep. 2019; 9(1):6987. PMC: 6502831. DOI: 10.1038/s41598-019-43531-w. View

4.
Chiu N, Fan S, Yang C, Huang T . Carboxyl-functionalized graphene oxide composites as SPR biosensors with enhanced sensitivity for immunoaffinity detection. Biosens Bioelectron. 2016; 89(Pt 1):370-376. DOI: 10.1016/j.bios.2016.06.073. View

5.
Erb E, Chen X, Allen S, Roberts C, Tendler S, Davies M . Characterization of the surfaces generated by liposome binding to the modified dextran matrix of a surface plasmon resonance sensor chip. Anal Biochem. 2000; 280(1):29-35. DOI: 10.1006/abio.1999.4469. View