Validation of Use of Transverse Acetabular Ligament and Mechanical Angle Guide Device to Orient the Acetabular Cup

Overview
Specialty Orthopedics
Date 2020 Oct 1
PMID 32999553
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: To verify if transverse acetabular ligament (TAL) can be used as an anatomical landmark to reliably orient the cup in primary total hip arthroplasty and compare it to acetabular cups placed with the help of mechanical angle guide (MAG) device.

Materials And Methods: Thirty Five patients with primary total hip arthroplasty, all performed by the same surgeon were included in the study. All patients had undergone surgery by anterolateral approach and all were cementless total hip arthroplasty. TAL was used as a reference guide for positioning of the cup in one group while MAG device was used in the other. Post operatively CT was done to confirm the version and inclination of the acetabular cup and the femoral stem version. SPSS was used for statistical analysis.

Results: 18 males and 17 females were included. The most common etiological cause for THR was secondary osteoarthritis due to AVN (40%). At 18 months follow up, there was just 1 case of dislocation in group in which angle guide device was used. The mean anteversion of the acetabular cup on CT findings was 23.82° by using TAL while 18.35° with help of MAG device (P < 0.05). All were within Leweniks safe zone.

Conclusions: The TAL and MAG device both can be effectively used to align the acetabulum component. TAL is patient specific intraoperative landmark which is not affected by patient positioning while angle guide device can give false positive assessment of cup version.

Citing Articles

Techniques and Technologies for the Intraoperative Assessment of Component Positioning, Leg Lengths, and Offset in Total Hip Arthroplasty: A Systematic Review.

Chung C, Bin Hazzaa I, Hakim R, Zywiel M Arthroplast Today. 2024; 27:101361.

PMID: 39071838 PMC: 11282408. DOI: 10.1016/j.artd.2024.101361.


Determining the orientation of acetabular prosthesis in total hip arthroplasty by refering to the anatomical landmarker of acetabular notches.

Zhang H, Zhou J, Ling X, Chen H, Du M, Zhao J Sci Rep. 2023; 13(1):6185.

PMID: 37061581 PMC: 10105719. DOI: 10.1038/s41598-023-33501-8.


Application of transverse acetabular ligament in total hip arthroplasty: a systematic review.

Ning D, Xu F, Zhang Z, Yang X, Wei J BMC Musculoskelet Disord. 2023; 24(1):284.

PMID: 37055756 PMC: 10099633. DOI: 10.1186/s12891-023-06410-0.

References
1.
Archbold H, Mockford B, Molloy D, McConway J, Ogonda L, Beverland D . The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability. J Bone Joint Surg Br. 2006; 88(7):883-6. DOI: 10.1302/0301-620X.88B7.17577. View

2.
Grammatopoulos G, Pandit H, da Assuncao R, Taylor A, McLardy-Smith P, De Smet K . Pelvic position and movement during hip replacement. Bone Joint J. 2014; 96-B(7):876-83. DOI: 10.1302/0301-620X.96B7.32107. View

3.
Hill J, Gibson D, Pagoti R, Beverland D . Photographic measurement of the inclination of the acetabular component in total hip replacement using the posterior approach. J Bone Joint Surg Br. 2010; 92(9):1209-14. DOI: 10.1302/0301-620X.92B9.24476. View

4.
Komeno M, Hasegawa M, Sudo A, Uchida A . Computed tomographic evaluation of component position on dislocation after total hip arthroplasty. Orthopedics. 2006; 29(12):1104-8. DOI: 10.3928/01477447-20061201-05. View

5.
DiGioia 3rd A, Jaramaz B, Plakseychuk A, Moody Jr J, Nikou C, Labarca R . Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty. 2002; 17(3):359-64. DOI: 10.1054/arth.2002.30411. View