» Articles » PMID: 32976563

Quantitative Fundus Autofluorescence in HCQ Retinopathy

Overview
Specialty Ophthalmology
Date 2020 Sep 25
PMID 32976563
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To increase our understanding of the mechanisms underlying hydroxychloroquine (HCQ) retinopathy, analyses by quantitative fundus autofluorescence (qAF) and near-infrared fundus autofluorescence (NIR-AF) were compared to results obtained by recommended screening tests.

Methods: Thirty-one patients (28 females, 3 males) were evaluated with standard automated perimetry and spectral domain optical coherence tomography (SD-OCT); 28 also had multifocal electroretinography (mfERG). Measurement of short-wavelength fundus autofluorescence (SW-AF) by qAF involved the use of an internal fluorescent reference and intensity measurements in eight concentric segments at 7° to 9° eccentricity. For semiquantitative analysis of NIR-AF, intensities were acquired along a vertical axis through the fovea.

Results: Four of 15 high-dose (total dose >1000 g, daily dose >5.0 mg/kg) patients and one of 16 low-dose (total dose <1000 g, daily dose 4.4 mg/kg) patients were diagnosed with HCQ-associated retinopathy based on abnormal 10-2 visual fields, SD-OCT, and SW-AF imaging. Three of the high-dose patients also had abnormal mfERG results. Of the five patients exhibiting retinopathy, two had qAF color-coded images revealing higher intensities inferior, nasal, and lateral to the fovea. The abnormal visual fields also exhibited superior-inferior differences. Mean NIR-AF gray-level intensities were increased in four high-dose patients with no evidence of retinopathy. In two patients with retinopathy, NIR-AF intensity within the parafovea was below the normal range. One high-dose patient (6.25 mg/kg) had only abnormal mfERG results.

Conclusions: These findings indicate that screening for HCQ retinopathy should take into consideration superior-inferior differences in susceptibility to HCQ retinopathy.

Citing Articles

Specificity protein 1/3 regulate T-cell acute lymphoblastic leukemia cell proliferation and apoptosis through β-catenin by acting as targets of miR-495-3p.

Zheng B, Geng Y, Li Y, Huang H, Liu A Ann Hematol. 2024; 103(8):2945-2960.

PMID: 38829410 DOI: 10.1007/s00277-024-05764-2.


Quantitative Fundus Autofluorescence in Systemic Chloroquine/Hydroxychloroquine Therapy: One Year Follow-Up.

Radun V, Berlin A, Tarau I, Kleefeldt N, Reichel C, Hillenkamp J Transl Vis Sci Technol. 2023; 12(7):8.

PMID: 37418250 PMC: 10337803. DOI: 10.1167/tvst.12.7.8.


Review of Retinal Imaging Modalities for Hydroxychloroquine Retinopathy.

Cheong K, Ong C, Chandrasekaran P, Zhao J, Teo K, Mathur R Diagnostics (Basel). 2023; 13(10).

PMID: 37238236 PMC: 10217485. DOI: 10.3390/diagnostics13101752.


Novel imaging techniques for hydroxychloroquine retinopathy.

Yusuf I, Charbel Issa P, Ahn S Front Med (Lausanne). 2022; 9:1026934.

PMID: 36314000 PMC: 9606779. DOI: 10.3389/fmed.2022.1026934.


Retinal microvasculature alteration in patients with systemic sclerosis and chloroquine treatment.

Huang T, Liang R, Zhang L, Shu H, Ge Q, Liao X Quant Imaging Med Surg. 2022; 12(10):4885-4899.

PMID: 36185048 PMC: 9511431. DOI: 10.21037/qims-21-1166.


References
1.
Melles R, Marmor M . Pericentral retinopathy and racial differences in hydroxychloroquine toxicity. Ophthalmology. 2014; 122(1):110-6. DOI: 10.1016/j.ophtha.2014.07.018. View

2.
Marmor M, Fulton A, Holder G, Miyake Y, Brigell M, Bach M . ISCEV Standard for full-field clinical electroretinography (2008 update). Doc Ophthalmol. 2008; 118(1):69-77. DOI: 10.1007/s10633-008-9155-4. View

3.
Chen E, Brown D, Benz M, Fish R, Wong T, Kim R . Spectral domain optical coherence tomography as an effective screening test for hydroxychloroquine retinopathy (the "flying saucer" sign). Clin Ophthalmol. 2010; 4:1151-8. PMC: 2964950. DOI: 10.2147/OPTH.S14257. View

4.
Sparrow J, Marsiglia M, Allikmets R, Tsang S, Lee W, Duncker T . Flecks in Recessive Stargardt Disease: Short-Wavelength Autofluorescence, Near-Infrared Autofluorescence, and Optical Coherence Tomography. Invest Ophthalmol Vis Sci. 2015; 56(8):5029-39. PMC: 4525681. DOI: 10.1167/iovs.15-16763. View

5.
Secondi R, Kong J, Blonska A, Staurenghi G, Sparrow J . Fundus autofluorescence findings in a mouse model of retinal detachment. Invest Ophthalmol Vis Sci. 2012; 53(9):5190-7. PMC: 3416030. DOI: 10.1167/iovs.12-9672. View