Background: To identify the main determinants of intraocular lens (IOL) tilt and decentration after cataract surgery using a novel anterior segment optical coherence tomography (AS-OCT) method.

Methods: Fifty-six patients who underwent phacoemulsification with IOL implantation in one eye were continuously enrolled in this cohort study. Axial length (AL) was measured with IOL Master 700. The tilt and decentration of patients' preoperative crystalline lenses and postoperative IOLs, as well as crystalline lens thickness (LT), were measured using AS-OCT before surgery and 1 week after surgery.

Results: The mean tilt and decentration of the patients' preoperative crystalline lenses were 4.90°±1.81° and 0.21±0.02 mm, and the mean tilt and decentration of IOLs were 4.75°±1.66° and 0.21±0.02 mm, respectively. There were no significant differences in magnitude, direction of tilt, or decentration between crystalline lenses and IOLs. The strongest determinant of IOL tilt was preoperative crystalline lens tilt (R=0.512, P<0.001), followed by AL (R=0.154, P=0.003). Additionally, crystalline lens decentration and AL explained 54.6% of the variability in IOL decentration. AL was the factor most highly associated with IOL decentration (R=0.332, P<0.001), rather than crystalline lens decentration (R=0.214, P<0.001).

Conclusions: The position of the preoperative crystalline lens and AL were the critical determinants of IOL tilt and decentration. The tilt and decentration of IOLs will be greater in patients with larger tilt and decentration of crystalline lenses, or shorter and longer AL.

Citing Articles

Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses.

Zhang Y, Zhang J, Liang C, Xu Y, Wu J, Wu J BMC Ophthalmol. 2025; 25(1):58.

PMID: 39901088 PMC: 11792569. DOI: 10.1186/s12886-025-03884-5.


A Comparative Analysis of the Effects of Misaligning Different Trifocal Intraocular Lenses.

Yan W, Auffarth G, Khoramnia R, Labuz G J Clin Med. 2025; 14(1.

PMID: 39797271 PMC: 11721922. DOI: 10.3390/jcm14010187.


Transcapsular scleral fixation of the standard capsular tension ring and in-the-bag intraocular lens implantation for severely subluxated lenses.

Li H, Yang F, Zhu Z, Zhao Y, Chang P, Zhao Y Int J Ophthalmol. 2024; 17(12):2321-2326.

PMID: 39697891 PMC: 11589438. DOI: 10.18240/ijo.2024.12.22.


Pilot Study on Postoperative Toric Intraocular Lens Alignment: Comparing Casia2 and Photoshop Imaging Techniques.

Yang B, Lai C, Qin Y, Lin H, Wang S, Liao H J Ophthalmol. 2024; 2024:1053914.

PMID: 39575317 PMC: 11581804. DOI: 10.1155/2024/1053914.


Analysis of intraocular lens tilt and decentration after cataract surgery in eyes with high myopia using the anterior segment optical coherence tomography.

Jeon Y, Park N, Lee H, Eah K, Han J, Chung H Sci Rep. 2024; 14(1):27987.

PMID: 39543310 PMC: 11564970. DOI: 10.1038/s41598-024-78759-8.


References
1.
Kimura S, Morizane Y, Shiode Y, Hirano M, Doi S, Toshima S . Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography. PLoS One. 2017; 12(9):e0184066. PMC: 5581187. DOI: 10.1371/journal.pone.0184066. View

2.
Wang L, de Souza R, Weikert M, Koch D . Evaluation of crystalline lens and intraocular lens tilt using a swept-source optical coherence tomography biometer. J Cataract Refract Surg. 2018; 45(1):35-40. DOI: 10.1016/j.jcrs.2018.08.025. View

3.
Lawu T, Mukai K, Matsushima H, Senoo T . Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye. J Cataract Refract Surg. 2019; 45(5):662-668. DOI: 10.1016/j.jcrs.2018.10.049. View

4.
Hirnschall N, Buehren T, Bajramovic F, Trost M, Teuber T, Findl O . Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography. J Cataract Refract Surg. 2017; 43(6):732-736. DOI: 10.1016/j.jcrs.2017.01.026. View

5.
Li L, Wang K, Yan Y, Song X, Liu Z . Research on calculation of the IOL tilt and decentration based on surface fitting. Comput Math Methods Med. 2013; 2013:572530. PMC: 3725812. DOI: 10.1155/2013/572530. View