» Articles » PMID: 32887083

Synthesis of MOF-derived Ni@C Materials for the Electrochemical Detection of Histamine

Overview
Journal Talanta
Publisher Elsevier
Specialty Chemistry
Date 2020 Sep 5
PMID 32887083
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Histamine (HA) plays an important role in food safety supervision and is also involved in various physiological functions. Accurate and rapid detection of HA in real sample is count for much as this is the significant prerequisite for its effective monitoring. In this study, we fabricated an electrochemical sensor to detect HA via the pyrolysis of the hydrothermal Ni-MOF (metal-organic frameworks), in which the obtained Ni@C material was deployed as the sensing agent. Ni@C was comprehensively characterized in terms of its morphology, constitution, as well as its electrochemical behavior. The as-prepared sensor (Ni@C/GCE) features excellent electrocatalytic activities. It was also observed that the electrochemical property of the sensor was substantially improved because Ni@C afforded an enlarged active surface and accelerated electron transport. This sensor affords amperometric analysis in the linear range of 10-100 μM HA with a 3.2 × 10 μM low detection limit (S/N = 3). Many important features, including decent anti-interference, reproducibility, stability, and reliability, were also observed. Importantly, the sensor enabled the measurement of HA in real samples obtained from fish, thus demonstrating its practical potential as a HA analytical detector.

Citing Articles

Spectro-Electrochemical Properties of A New Non-Enzymatic Modified Working Electrode Used for Histamine Assessment in the Diagnosis of Food Poisoning.

Iordache S, Iordache A, Zubarev A, Caramizoiu S, Grigorescu C, Marinescu S Foods. 2023; 12(15).

PMID: 37569178 PMC: 10417452. DOI: 10.3390/foods12152908.


Manganese cobalt-MOF@carbon nanofiber-based non-enzymatic histamine sensor for the determination of food freshness.

Dey B, Ahmad M, Kim B, Kamal T, Yang D, Patra C Anal Bioanal Chem. 2023; 415(17):3487-3501.

PMID: 37219581 DOI: 10.1007/s00216-023-04737-0.


Graphene-Based Sensor for the Detection of Cortisol for Stress Level Monitoring and Diagnostics.

Zubarev A, Cuzminschi M, Iordache A, Iordache S, Rizea C, Grigorescu C Diagnostics (Basel). 2022; 12(11).

PMID: 36359436 PMC: 9689560. DOI: 10.3390/diagnostics12112593.


Construction of Electrochemical Aptamer Sensor Based on Pt-Coordinated Titanium-Based Porphyrin MOF for Thrombin Detection.

Jiang J, Cai Q, Deng M Front Chem. 2022; 9:812983.

PMID: 35071191 PMC: 8776986. DOI: 10.3389/fchem.2021.812983.


Aptamer and bifunctional enzyme co-functionalized MOF-derived porous carbon for low-background electrochemical aptasensing.

Wan H, Cao X, Liu M, Zhang F, Sun C, Xia J Anal Bioanal Chem. 2021; 413(25):6303-6312.

PMID: 34396471 DOI: 10.1007/s00216-021-03585-0.