» Articles » PMID: 32821485

Spectral Domain Optical Coherence Tomography in Awake Rabbits Allows Identification of the Visual Streak, a Comparison with Histology

Overview
Date 2020 Aug 22
PMID 32821485
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate visual streak (VS) identification on spectral-domain optical coherence tomography (SD-OCT) scans in awake rabbits. To report thickness measurements in the VS and adjacent retina on OCT B-scans and histologic sections and to assess inter-method bias, precision and repeatability between OCT and histology.

Methods: Vertical SD-OCT B-scan images through the optic nerve head and VS were acquired from 16 awake, ophthalmologically healthy experimental rabbits. Scans were acquired from both eyes, which were later enucleated and processed for light microscopy. Inner retina, inner nuclear layer, outer nuclear layer, outer retina (OR) and photoreceptor outer segment (PROS) thickness were measured on OCT images and digitalized microscopy slides in- and outside of the VS, and compared using linear mixed effects models.

Results: Both SD-OCT and histology allowed retinal layer identification and measurement. On OCT, OR and PROS were thickest in the central VS and thinnest outside the VS. Histology mirrored OCT results for central outer retinal layers but shows discrepancies for other layers likely because of postmortem processing artifacts. The method comparison demonstrated better repeatability for OCT measurements compared with histology.

Conclusions: Increased OR and PROS thickness compared with the adjacent retina allowed identification of the VS on SD-OCT in awake rabbits. OCT allows measurements devoid of processing artifacts in contrast to histology.

Translational Relevance: SD-OCT is possible in awake rabbits. Easy and reliable identification of the VS may facilitate the positioning and use of rabbits as model species in human macular and generalized retinal disease research.

Citing Articles

Intraoperative quantitative crystalline lens nuclear opacities analysis based on crystalline lenSx platform.

Zhang Y, Zhang Y, Zhang J, Wang T, Yi L, Zeng Y BMC Ophthalmol. 2024; 24(1):206.

PMID: 38711059 PMC: 11071230. DOI: 10.1186/s12886-024-03431-8.


Early detection of optic nerve head changes using optical coherence tomography after using mesenchymal stromal cells as intravitreal therapy in rabbit models of ocular hypertension.

Evangelho K, Cifuentes-Gonzalez C, Rojas-Carabali W, Vivero-Arciniegas C, Canas-Arboleda M, Salguero G Vet World. 2024; 17(2):500-508.

PMID: 38595669 PMC: 11000475. DOI: 10.14202/vetworld.2024.500-508.


Detection sensitivity of fluorescence lifetime imaging ophthalmoscopy for laser-induced selective damage of retinal pigment epithelium.

Sonntag S, Hamann M, Seifert E, Grisanti S, Brinkmann R, Miura Y Graefes Arch Clin Exp Ophthalmol. 2024; 262(9):2885-2895.

PMID: 38587656 PMC: 11377681. DOI: 10.1007/s00417-024-06449-2.


Normative Data of Axial Length, Retinal Thickness Measurements, Visual Evoked Potentials, and Full-Field Electroretinography in Female, Wild-Type Minipigs.

Choi K, Anh V, Oh J, Yun C, Kim S Transl Vis Sci Technol. 2021; 10(12):3.

PMID: 34605876 PMC: 8496425. DOI: 10.1167/tvst.10.12.3.


Fluorescence Lifetime Changes Induced by Laser Irradiation: A Preclinical Study towards the Evaluation of Retinal Metabolic States.

Sonntag S, Seifert E, Hamann M, Lewke B, Theisen-Kunde D, Grisanti S Life (Basel). 2021; 11(6).

PMID: 34199212 PMC: 8231852. DOI: 10.3390/life11060555.

References
1.
Muraoka Y, Ikeda H, Nakano N, Hangai M, Toda Y, Okamoto-Furuta K . Real-time imaging of rabbit retina with retinal degeneration by using spectral-domain optical coherence tomography. PLoS One. 2012; 7(4):e36135. PMC: 3338600. DOI: 10.1371/journal.pone.0036135. View

2.
Knott E, Sheets K, Zhou Y, Gordon W, Bazan N . Spatial correlation of mouse photoreceptor-RPE thickness between SD-OCT and histology. Exp Eye Res. 2010; 92(2):155-60. PMC: 3169798. DOI: 10.1016/j.exer.2010.10.009. View

3.
Sanchez-Cano A, Baraibar B, Pablo L, Honrubia F . Magnification characteristics of the Optical Coherence Tomograph STRATUS OCT 3000. Ophthalmic Physiol Opt. 2008; 28(1):21-8. DOI: 10.1111/j.1475-1313.2007.00527.x. View

4.
Hughes A . Topographical relationships between the anatomy and physiology of the rabbit visual system. Doc Ophthalmol. 1971; 30:33-159. DOI: 10.1007/BF00142518. View

5.
Oishi A, Hata M, Shimozono M, Mandai M, Nishida A, Kurimoto Y . The significance of external limiting membrane status for visual acuity in age-related macular degeneration. Am J Ophthalmol. 2010; 150(1):27-32.e1. DOI: 10.1016/j.ajo.2010.02.012. View