Effects of Expiratory Flow Resistance on Inspiratory Work of Breathing

Overview
Journal Chest
Publisher Elsevier
Specialty Pulmonary Medicine
Date 1988 Apr 1
PMID 3280260
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

To minimize work of breathing, airway pressure should not fluctuate during spontaneous breathing with continuous positive airway pressure (CPAP). However, flow resistance in the inspiratory limb of the breathing circuit and an inadequate continuous gas flow rate result in airway pressure fluctuation and increased work of breathing. Flow resistance of the expiratory pressure/exhalation valve also directly affects the level of airway pressure during spontaneous inhalation with CPAP (the greater the resistance of the valve, the greater the decrease in airway pressure and work of breathing). We compared this effect with three types of expiratory pressure valves: a threshold resistor with low resistance to flow, an inflatable balloon (mushroom) valve with moderate resistance to flow, and a variable-orifice flow resistor with a high resistance to flow. Work increased up to threefold with the balloon valve and more than tenfold with the flow resistor compared with the threshold resistor. To apply CPAP, expiratory pressure valves with low resistance to flow should be used to minimize fluctuations in airway pressure and, thus, in the work of spontaneous breathing.

Citing Articles

Evaluation and application of a method for estimating nasal end-tidal O fraction while administering supplemental O.

Burk K, Kuck K, Orr J J Clin Monit Comput. 2019; 33(6):1071-1080.

PMID: 30725266 DOI: 10.1007/s10877-019-00264-5.


Unloading work of breathing during high-frequency oscillatory ventilation: a bench study.

VAN Heerde M, Roubik K, Kopelent V, Plotz F, Markhorst D Crit Care. 2006; 10(4):R103.

PMID: 16848915 PMC: 1750967. DOI: 10.1186/cc4968.


Work of breathing, inspiratory flow response, and expiratory resistance during continuous positive airway pressure with the ventilators EVITA-2, EVITA-4 and SV 300.

Calzia E, Lindner K, Stahl W, Martin A, Radermacher P, Georgieff M Intensive Care Med. 1998; 24(9):931-8.

PMID: 9803329 DOI: 10.1007/s001340050692.


Re-engineering ventilatory support to decrease days and improve resource utilization.

Kirton O, DeHaven C, Morgan J, Windsor J, Civetta J Ann Surg. 1996; 224(3):396-402; discussion 402-4.

PMID: 8813268 PMC: 1235390. DOI: 10.1097/00000658-199609000-00016.


Superimposed inspiratory work of the Siemens Servo 300 ventilator during continuous positive airway pressure.

Tan I, Bhatt S, Tam Y, Buckley T, Oh T Intensive Care Med. 1995; 21(12):1023-6.

PMID: 8750128 DOI: 10.1007/BF01700665.