Ultrahigh-Throughput ESI-MS: Sampling Pushed to Six Samples Per Second by Acoustic Ejection Mass Spectrometry

Overview
Journal Anal Chem
Specialty Chemistry
Date 2020 Aug 14
PMID 32786476
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

We present an acoustic ejection mass spectrometry (AEMS) setup for contactless electrospray ionization mass spectrometry (ESI-MS)-based sample injection at a sampling rate faster than current ESI and matrix-assisted laser desorption ionization (MALDI) techniques. For the direct transfer of samples out of 384-well plates into a modified ESI source, an open port interface (OPI) was combined with a modified acoustic droplet ejection (ADE) system. AEMS has the potential to eliminate bottlenecks known from classical MS approaches, such as speed, reproducibility, carryover, ion suppression, as well as sample preparation and consumption. This setup provided a drastically reduced transfer distance between OPI and ESI electrode for optimum throughput performance and broadens the scope of applications for this emerging technique. To simulate label-free applications of drug metabolism and pharmacokinetics (DMPK) analysis and high-throughput screening (HTS) campaigns, two stress tests were performed regarding ion suppression and system endurance in combination with minor sample preparation. The maximum sampling rate was 6 Hz for dextromethorphan and -dextrorphan (each 100 nM) for 1152 injections in 63 s at full width at half-maximum (FWHM) of 105 ms and a relative standard deviation (%RSD) of 7.7/7.5% without internal standard correction. Enzyme assay buffer and crude dog plasma caused signal suppression of 51/73% at %RSD of 5.7/6.7% ( = 120). An HTS endurance buffer was used for >25 000 injections with minor OPI pollution and constant signals (%RSD = 8.5%, FWHM of 177 ms ± 8.5%, = 10 557). The optimized hardware and method setup resulted in high-throughput performance and enables further implementation in a fully automated platform for ESI-MS-based high-throughput screening.

Citing Articles

Automated and integrated ultrahigh throughput screening for industrial strain enabled by acoustic-droplet-ejection mass spectrometry.

Zhang Z, Zhang C, Zhang X, Chen J, Cai N, Zhong S J Pharm Anal. 2024; 14(9):100949.

PMID: 39291242 PMC: 11402536. DOI: 10.1016/j.jpha.2024.02.003.


Development of a high-throughput dual-stream liquid chromatography-tandem mass spectrometry method to screen for inhibitors of glutamate carboxypeptidase II.

Hoxie N, Qiu Y, Kales S, Schneider R, Hu X, Dalal A Rapid Commun Mass Spectrom. 2024; e9772.

PMID: 38867136 PMC: 11737842. DOI: 10.1002/rcm.9772.


Recent advances in analytical techniques for high throughput experimentation.

Vervoort N, Goossens K, Baeten M, Chen Q Anal Sci Adv. 2024; 2(3-4):109-127.

PMID: 38716456 PMC: 10989611. DOI: 10.1002/ansa.202000155.


"What I wish I had known before starting my PhD".

Wiebach V Anal Sci Adv. 2024; 4(1-2):6-12.

PMID: 38715583 PMC: 10989638. DOI: 10.1002/ansa.202200044.


A Comprehensive Review of Surface Acoustic Wave-Enabled Acoustic Droplet Ejection Technology and Its Applications.

Ning J, Lei Y, Hu H, Gai C Micromachines (Basel). 2023; 14(8).

PMID: 37630082 PMC: 10456473. DOI: 10.3390/mi14081543.