» Articles » PMID: 32746236

Displacement Imaging During Focused Ultrasound Median Nerve Modulation: A Preliminary Study in Human Pain Sensation Mitigation

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

Focused ultrasound (FUS)-based viscoelastic imaging techniques using high frame rate (HFR) ultrasound to track tissue displacement can be used for mechanistic monitoring of FUS neuromodulation. However, a majority of techniques avoid imaging during the active push transmit (interleaved or postpush acquisitions) to mitigate ultrasound interference, which leads to missing temporal information of ultrasound effects when FUS is being applied. Furthermore, critical for clinical translation, use of both axial steering and real-time (<1 s) capabilities for optimizing acoustic parameters for tissue engagement are largely missing. In this study, we describe a method of noninterleaved, single Vantage imaging displacement within an active FUS push with simultaneous axial steering and real-time capabilities using a single ultrasound acquisition machine. Results show that the pulse sequence can track micron-sized displacements using frame rates determined by the calculated time-of-flight (TOF), without interleaving the FUS pulses and imaging acquisition. Decimation by 3-7 frames increases signal-to-noise ratio (SNR) by 15.09±7.03 dB. Benchmarking tests of CUDA-optimized code show increase in processing speed of 35- and 300-fold in comparison with MATLAB parallel processing GPU and CPU functions, respectively, and we can estimate displacement from steered push beams ±10 mm from the geometric focus. Preliminary validation of displacement imaging in humans shows that the same driving pressures led to variable nerve engagement, demonstrating important feedback to improve transducer coupling, FUS incident angle, and targeting. Regarding the use of our technique for neuromodulation, we found that FUS altered thermal perception of thermal pain by 0.9643 units of pain ratings in a single trial. Additionally, 5 [Formula: see text] of nerve displacement was shown in on-target versus off-target sonications. The initial feasibility in healthy volunteers warrants further study for potential clinical translation of FUS for pain suppression.

Citing Articles

Compound Acoustic Radiation Force Impulse Imaging of Bovine Eye by Using Phase-Inverted Ultrasound Transducer.

Kim G, Moon H, Lee H, Jeong J Sensors (Basel). 2024; 24(9).

PMID: 38732804 PMC: 11085659. DOI: 10.3390/s24092700.


Functional Cerebral Neurovascular Mapping During Focused Ultrasound Peripheral Neuromodulation of Neuropathic Pain.

Lee S, Kamimura H, Smith M, Konofagou E IEEE Trans Biomed Eng. 2024; 71(6):1770-1779.

PMID: 38198257 PMC: 11105977. DOI: 10.1109/TBME.2024.3352025.


Optimization of the Tracking Beam Sequence in Harmonic Motion Imaging.

Liu Y, Saharkhiz N, Hossain M, Konofagou E IEEE Trans Ultrason Ferroelectr Freq Control. 2023; 71(1):102-116.

PMID: 37917522 PMC: 10871064. DOI: 10.1109/TUFFC.2023.3329729.


Interdependence of Tissue Temperature, Cavitation, and Displacement Imaging During Focused Ultrasound Nerve Sonication.

McCune E, Lee S, Konofagou E IEEE Trans Ultrason Ferroelectr Freq Control. 2023; 70(7):600-612.

PMID: 37256815 PMC: 10332467. DOI: 10.1109/TUFFC.2023.3280455.


Peripheral focused ultrasound stimulation and its applications: From therapeutics to human-computer interaction.

Bao S, Li F, Xiao Y, Niu L, Zheng H Front Neurosci. 2023; 17:1115946.

PMID: 37123351 PMC: 10140332. DOI: 10.3389/fnins.2023.1115946.


References
1.
Maleke C, Konofagou E . In vivo feasibility of real-time monitoring of focused ultrasound surgery (FUS) using harmonic motion imaging (HMI). IEEE Trans Biomed Eng. 2009; 57(1):7-11. DOI: 10.1109/TBME.2009.2027423. View

2.
Baek H, Pahk K, Kim H . A review of low-intensity focused ultrasound for neuromodulation. Biomed Eng Lett. 2019; 7(2):135-142. PMC: 6208465. DOI: 10.1007/s13534-016-0007-y. View

3.
Dhanaliwala A, Hossack J, Mauldin F . Assessing and improving acoustic radiation force image quality using a 1.5-D transducer design. IEEE Trans Ultrason Ferroelectr Freq Control. 2012; 59(7):1602-8. PMC: 4047991. DOI: 10.1109/TUFFC.2012.2360. View

4.
Shamdasani V, Kim Y . Two-dimensional autocorrelation method for ultrasound-based strain estimation. Conf Proc IEEE Eng Med Biol Soc. 2007; 2004:1380-3. DOI: 10.1109/IEMBS.2004.1403430. View

5.
Hoffman B, Baba Y, Lee S, Tong C, Konofagou E, Lumpkin E . Focused ultrasound excites action potentials in mammalian peripheral neurons in part through the mechanically gated ion channel PIEZO2. Proc Natl Acad Sci U S A. 2022; 119(21):e2115821119. PMC: 9173751. DOI: 10.1073/pnas.2115821119. View