Comparison of Predictability Using Barrett Universal II and SRK/T Formulas According to Keratometry
Overview
Affiliations
Purpose: To compare the predictability of intraocular lens (IOL) power calculation using the Barrett Universal II and the SRK/T formulas, according to the keratometry.
Methods: We retrospectively reviewed the clinical charts of 335 consecutive eyes undergoing standard cataract surgery. IOL power calculations were performed using the Barrett Universal II and the SRK/T formulas. We compared the prediction error, the absolute error, and the percentages within ±0.25, ±0.5, and ±1.0 D of the targeted refraction, 1 month postoperatively, and also investigated the relationship of these outcomes with the keratometric readings, using the two formulas.
Results: The prediction error using the SRK/T formula was significantly more myopic than that using the Barrett Universal II formula (the paired -test, < 0.001). The absolute error using the SRK/T formula was significantly larger than that using the Barrett Universal II formula (=0.006). We found a significant correlation between the prediction error and the keratometric readings using the SRK/T formula (Pearson correlation coefficient, = -0.522, < 0.001), but there was no significant correlation between them using the Barrett Universal II formula ( = -0.031, =0.576).
Conclusions: The Barrett Universal II formula provides a better predictability of IOL power calculation and is less susceptible to the effect of the corneal shape, than the SRK/T formula. The Barrett Universal formula, instead of the SRK/T formula, may be clinically helpful for improving the refractive accuracy, especially in eyes with steep or flat corneas.
Comparison of two formulas for calculating intraocular lens in patients with angle-closure glaucoma.
Ji Z, Ma J, Sun Z, Zhang M Medicine (Baltimore). 2024; 103(45):e40387.
PMID: 39533616 PMC: 11556955. DOI: 10.1097/MD.0000000000040387.
Lim H, Jang J, Nam S, Lee K, Kim J, Tchah H Korean J Ophthalmol. 2023; 38(1):9-16.
PMID: 38110185 PMC: 10869425. DOI: 10.3341/kjo.2023.0039.
Tran K, Nguyen T Saudi J Ophthalmol. 2023; 37(3):237-240.
PMID: 38074294 PMC: 10701144. DOI: 10.4103/sjopt.sjopt_19_23.
Residual refractive errors in pseudophakic eyes and related factors: a population-based study.
Hashemi H, Jamali A, Rezavn F, Hashemi A, Khabazkhoob M Int J Ophthalmol. 2023; 16(5):778-786.
PMID: 37206186 PMC: 10172090. DOI: 10.18240/ijo.2023.05.16.
Yin S, Guo C, Qiu K, Ng T, Li Y, Du Y Int Ophthalmol. 2022; 42(10):3211-3219.
PMID: 36057757 DOI: 10.1007/s10792-022-02322-5.