Background: Invasive mechanical ventilation (MV) is lifesaving for critically ill neonates. Limiting the duration of MV support is crucial. Lung ultrasonography is a bedside technique useful to predict weaning success in adults, but few data are available about its use in neonates. Our aim was to assess the value of lung ultrasonography to predict weaning success of the ventilated neonates.

Methods: This study included 80 neonates on MV suffering from different pulmonary diseases. All patients had lung ultrasound just before extubation and 6 hours after extubation. Lung ultrasound score (LUS) was calculated for all neonate. Blood gases and chest x-ray were performed just before extubation as well. All neonates were followed up for 48 hours after extubation for extubation failure (EF).

Results: Eighteen neonates (22.5%) experienced EF. Neonates with EF had significantly lower gestational age, lower weight but significantly prolonged duration of MV, prolonged NICU stay, and higher mortality. LUS before and after extubation was significantly higher in neonates with EF than those with weaning success. Pre-extubation LUS had a sensitivity of 83% and a specificity of 88% to predict weaning success in neonates at a cutoff value ≤4. While, post-extubation LUS had a sensitivity of 89%, and a specificity of 90% to predict weaning success in neonates at a cutoff point ≤6.

Conclusion: Lung ultrasound is a rapid, noninvasive, repetitive, and reliable tool for predicting the weaning success of ventilated neonates.

Citing Articles

Predicting extubation failure in neonates: The role of lung ultrasound and corrected gestational age in safe weaning in the NICU.

Rojas B, Procianoy R, de Souza A, Rigodanzo C, Trindade G, Furlan S Eur J Pediatr. 2025; 184(2):144.

PMID: 39825155 DOI: 10.1007/s00431-025-05977-1.


Accuracy of lung ultrasound in predicting successful extubation in preterm infants born ≤ 25 weeks.

Zong H, Lin B, Huang Y, Huang Y, Sun H, Xu Q J Perinatol. 2025; .

PMID: 39809972 DOI: 10.1038/s41372-024-02206-9.


Association of Lung Ultrasound Scores With Different Modes of Respiratory Support and Clinical Outcomes: An Observational Study in a Tertiary Care Neonatal Unit.

Pathak K, Maria A, Guleria M, Mall P, Sharma A Cureus. 2024; 16(8):e66199.

PMID: 39233940 PMC: 11373734. DOI: 10.7759/cureus.66199.


Lung ultrasound score as a tool to predict severity of bronchopulmonary dysplasia in neonates born ≤25 weeks of gestational age.

Zong H, Huang Z, Fu Y, Chen X, Yu Y, Huang Y J Perinatol. 2023; 44(2):273-279.

PMID: 38087005 DOI: 10.1038/s41372-023-01811-4.


Prognostic Relevance of the Lung Ultrasound Score: A Multioutcome Study in Infants with Respiratory Distress Syndrome.

Szymanski P, Puskarz-Gasowska J, Hozejowski R, Stefanska M, Blaz W, Sadowska-Krawczenko I Am J Perinatol. 2023; 41(S 01):e2862-e2869.

PMID: 37848043 PMC: 11150063. DOI: 10.1055/s-0043-1775975.