» Articles » PMID: 32601661

On the Reliability of Suction Measurements for Skin Characterization

Overview
Journal J Biomech Eng
Date 2020 Jul 1
PMID 32601661
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

in vivo skin characterization methods were shown to be useful in the detection of microstructural alterations of the dermis due to skin diseases. Specifically, the diagnostic potential of skin suction has been widely explored, yet measurement uncertainties prevented so far its application in clinical assessment. In this work, we analyze specific factors influencing the reliability of suction measurements. We recently proposed a novel suction device, called Nimble, addressing the limitations of existing instruments, and applied it in clinical trials quantifying mechanical differences between healthy skin and scars. Measurements were performed with the commercial device Cutometer and with the new device. A set of new suction measurements was carried out on scar tissue and healthy skin, and FE-based inverse analysis was applied to determine corresponding parameters of a hyperelastic-viscoelastic material model. FE simulations were used to rationalize differences between suction protocols and to analyze specific factors influencing the measurement procedure. Tissue stiffness obtained from Cutometer measurements was significantly higher compared to the one from Nimble measurements, which was shown to be associated with the higher deformation levels in the Cutometer and the nonlinear mechanical response of skin. The effect of the contact force exerted on skin during suction measurements was quantified, along with an analysis of the effectiveness of a corresponding correction procedure. Parametric studies demonstrated the inherently higher sensitivity of displacement- over load-controlled suction measurements, thus rationalizing the superior ability of the Nimble to distinguish between tissues.

Citing Articles

The Histological and Mechanical Behavior of Skin During Puncture for Different Impactor Sizes and Loading Rates.

LeSueur J, Koser J, Dzwierzynski W, Stemper B, Hampton C, Kleinberger M Ann Biomed Eng. 2025; .

PMID: 40053222 DOI: 10.1007/s10439-025-03699-x.


On modeling the multiscale mechanobiology of soft tissues: Challenges and progress.

Guo Y, Mofrad M, Tepole A Biophys Rev (Melville). 2024; 3(3):031303.

PMID: 38505274 PMC: 10903412. DOI: 10.1063/5.0085025.


Data-driven Tissue Mechanics with Polyconvex Neural Ordinary Differential Equations.

Tac V, Sahli Costabal F, Tepole A Comput Methods Appl Mech Eng. 2023; 398.

PMID: 38045634 PMC: 10691864. DOI: 10.1016/j.cma.2022.115248.


Data-driven Modeling of the Mechanical Behavior of Anisotropic Soft Biological Tissue.

Tac V, Sree V, Rausch M, Tepole A Eng Comput. 2023; 38(5):4167-4182.

PMID: 38031587 PMC: 10686525. DOI: 10.1007/s00366-022-01733-3.


Intra- and inter-rater reliabilities of skin mechanical properties measured in healthy individuals using skin elasticity meter.

Fujimoto Y, Yuri Y, Kato Y, Kinoshita S, Tamiya H Ann Med. 2023; 55(2):2279747.

PMID: 37967233 PMC: 10653741. DOI: 10.1080/07853890.2023.2279747.