» Articles » PMID: 32522913

Biological Responses to Pediatric Stainless Steel Crowns

Overview
Journal J Oral Sci
Specialty Dentistry
Date 2020 Jun 12
PMID 32522913
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

A systematic review was conducted to identify the biological responses, allergic reaction, hypersensitivity, toxicity, and ion release profile associated with pediatric stainless steel crowns (SSCs) in the existing literature. A systematic search was undertaken according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. The inclusion criteria consisted of patients younger than 20 years of age with SSC placement on primary or permanent teeth and in vivo and in vitro exposure to SSCs. Outcomes measures included adverse oral/mucosal effects; removal/failure/replacement of the SSC; type of allergic reaction; nickel (Ni) or other ion levels in bodily fluids, cellular, genotoxic, cytotoxic, mutagenic or carcinogenic effects related to the SSC. After an initial search of 764 studies in the database, 17 articles were included in the analysis. Evidence of allergic reactions to SSCs in children is limited and obtained from mostly low-quality research. Some studies showed that the amount of Ni detected was less than the amount ingested in the daily diet. In contrast, other studies reported a significantly higher release of Ni occurred into the saliva in acidic environments. There is some concern about the leaching of metal ions such as Ni from SSCs in children at high risk for caries. Further long-term studies are required to investigate this phenomenon.

Citing Articles

Clinical study of the effect of the metal precrown restoration in the first deciduous molar on the composite resin filling in the second deciduous molar.

Wang C, Zhang Y Hua Xi Kou Qiang Yi Xue Za Zhi. 2024; 42(6):773-777.

PMID: 39610074 PMC: 11669937. DOI: 10.7518/hxkq.2024.2024189.


Efficacy evaluation of zirconia crown on primary molars with caries defects.

Deng S, Niu S, Gao Q, Zhang L, Chen Z, Liu M Hua Xi Kou Qiang Yi Xue Za Zhi. 2024; 42(5):652-659.

PMID: 39304509 PMC: 11493868. DOI: 10.7518/hxkq.2024.2024122.


Biocompatibility and acid resistance of preformed crowns in children: an in vitro study.

Hogerheyde T, Coates D, Walsh L, Zafar S Eur Arch Paediatr Dent. 2024; 25(3):417-425.

PMID: 38662172 PMC: 11233320. DOI: 10.1007/s40368-024-00898-3.


Early Interceptive Correction for Anterior Crossbite Using a Removable Appliance: A Pediatric Case Study.

Almarhoumi A, Alwafi M Cureus. 2024; 16(3):e56072.

PMID: 38482533 PMC: 10934060. DOI: 10.7759/cureus.56072.


Tribological Behavior of TiO PEEK Composite and Stainless Steel for Pediatric Crowns.

Arieira A, Madeira S, Rodrigues F, Silva F Materials (Basel). 2023; 16(6).

PMID: 36984300 PMC: 10053974. DOI: 10.3390/ma16062420.