» Articles » PMID: 32520952

Reliability of Technologies to Measure the Barbell Velocity: Implications for Monitoring Resistance Training

Overview
Journal PLoS One
Date 2020 Jun 11
PMID 32520952
Citations 30
Authors
Affiliations
Soon will be listed here.
Abstract

This study investigated the inter- and intra-device agreement of four new devices marketed for barbell velocity measurement. Mean, mean propulsive and peak velocity outcomes were obtained for bench press and full squat exercises along the whole load-velocity spectrum (from light to heavy loads). Measurements were simultaneously registered by two linear velocity transducers T-Force, two linear position transducers Speed4Lifts, two smartphone video-based systems My Lift, and one 3D motion analysis system STT. Calculations included infraclass correlation coefficient (ICC), Bland-Altman Limits of Agreement (LoA), standard error of measurement (SEM), smallest detectable change (SDC) and maximum errors (MaxError). Results were reported in absolute (m/s) and relative terms (%1RM). Three velocity segments were differentiated according to the velocity-load relationships for each exercise: heavy (≥ 80% 1RM), medium (50% < 1RM < 80%) and light loads (≤ 50% 1RM). Criteria for acceptable reliability were ICC > 0.990 and SDC < 0.07 m/s (~5% 1RM). The T-Force device shown the best intra-device agreement (SDC = 0.01-0.02 m/s, LoA <0.01m/s, MaxError = 1.3-2.2%1RM). The Speed4Lifts and STT were found as highly reliable, especially against lifting velocities ≤1.0 m/s (Speed4Lifts, SDC = 0.01-0.05 m/s; STT, SDC = 0.02-0.04 m/s), whereas the My Lift app showed the worst results with errors well above the acceptable levels (SDC = 0.26-0.34 m/s, MaxError = 18.9-24.8%1RM). T-Force stands as the preferable option to assess barbell velocity and to identify technical errors of measurement for emerging monitoring technologies. Both the Speed4Lifts and STT are fine alternatives to T-Force for measuring velocity against high-medium loads (velocities ≤ 1.0 m/s), while the excessive errors of the newly updated My Lift app advise against the use of this tool for velocity-based resistance training.

Citing Articles

Is the EnodePro a Valid Tool to Determine the Bar Velocity in the Bench Press and Barbell Back Squat? A Comparative Analysis.

Behrmann N, Hillebrecht M, Afonso J, Warneke K Sensors (Basel). 2025; 25(2.

PMID: 39860918 PMC: 11769546. DOI: 10.3390/s25020549.


Validity of a New Portable Sensor to Measure Velocity-Based Resistance Training.

Justo-Alvarez A, Garcia-Lopez J, Sabido R, Garcia-Valverde A Methods Protoc. 2025; 8(1.

PMID: 39846695 PMC: 11755614. DOI: 10.3390/mps8010009.


Comparison of Velocity and Estimated One Repetition Maximum Measured with Different Measuring Tools in Bench Presses and Squats.

van den Tillaar R, Nygaard Falch H, Larsen S Sensors (Basel). 2024; 24(23).

PMID: 39685958 PMC: 11644249. DOI: 10.3390/s24237422.


Acute Effect of Fixed vs. Self-Selected Rest Interval Between Sets on Physiological and Performance-Related Responses.

Alonso-Aubin D, Hernandez-Lougedo J, Cavero-Haro A, Martinez-Guardado I J Funct Morphol Kinesiol. 2024; 9(4).

PMID: 39449494 PMC: 11503322. DOI: 10.3390/jfmk9040200.


Validity and reliability of velocity and power measures provided by the Vitruve linear position transducer.

Ruiz-Alias S, Senturk D, Akyildiz Z, Cetin O, Kaya S, Perez-Castilla A PLoS One. 2024; 19(10):e0312348.

PMID: 39446844 PMC: 11500865. DOI: 10.1371/journal.pone.0312348.


References
1.
Banyard H, Nosaka K, Sato K, Haff G . Validity of Various Methods for Determining Velocity, Force, and Power in the Back Squat. Int J Sports Physiol Perform. 2017; 12(9):1170-1176. DOI: 10.1123/ijspp.2016-0627. View

2.
Revicki D, Hays R, Cella D, Sloan J . Recommended methods for determining responsiveness and minimally important differences for patient-reported outcomes. J Clin Epidemiol. 2008; 61(2):102-9. DOI: 10.1016/j.jclinepi.2007.03.012. View

3.
Appleby B, Banyard H, Cormack S, Newton R . Validity and Reliability of Methods to Determine Barbell Displacement in Heavy Back Squats: Implications for Velocity-Based Training. J Strength Cond Res. 2020; 34(11):3118-3123. DOI: 10.1519/JSC.0000000000002803. View

4.
Pallares J, Lopez-Samanes A, Fernandez-Elias V, Aguado-Jimenez R, Ortega J, Gomez C . Pseudoephedrine and circadian rhythm interaction on neuromuscular performance. Scand J Med Sci Sports. 2014; 25(6):e603-12. DOI: 10.1111/sms.12385. View

5.
Sanchez-Medina L, Pallares J, Perez C, Moran-Navarro R, Gonzalez-Badillo J . . Sports Med Int Open. 2018; 1(2):E80-E88. PMC: 6226068. DOI: 10.1055/s-0043-102933. View