» Articles » PMID: 32415555

Pulmonary Vein Isolation Using Second-generation Single-shot Devices: Not All the Same?

Overview
Publisher Springer
Date 2020 May 17
PMID 32415555
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Single-shot devices have been developed to simplify pulmonary vein isolation (PVI). Randomized studies of the second-generation cryoballoon (CB 2nd) demonstrated excellent results. There are limited data comparing results of circular pulmonary vein ablation catheter (PVAC) with conventional RF ablation or CB for PVI.

Objective: Using a sequential registry cohort and a prospective randomized study, we aimed to compare the acute and long-term results of CB 2nd and PVAC Gold.

Methods: In the registry, consecutive patients with paroxysmal atrial fibrillation (AF) undergoing their first PVI were included. The preferred method used was PVAC Gold in 2014 and CB 2nd in 2015. Subsequently, a randomized study (PVAC vs. CB 2nd) was performed. Ablation success was measured as freedom of AF or atrial tachycardias (AT) off antiarrhythmic drugs.

Results: In the registry cohort, PVAC Gold was used in 60 patients and CB 2nd in 56 patients (age 66 ± 11 years, 52% male, LAD 43 ± 6). In the randomized study, 20 patients were treated with PVAC Gold and 22 with CB 2nd (age 67 ± 9; 43% men, LAD 40 ± 7 mm). During a mean follow up of 13.2 ± 3.6 months, success was 54% in PVAC Gold patients and 81% in CB 2nd cases (p = 0.001). In the randomized study 12 months success was 50% versus 86%, p < 0.05. Complications occurred rare in both groups.

Conclusions: Our registry data and the randomized study both suggest superiority of PVI using CB 2nd as compared with PVI using PVAC Gold.

Citing Articles

2-year outcomes of phased radiofrequency ablation for atrial fibrillation with the second-generation PVAC Gold ablation catheter.

Klaver M, Wintgens L, Wijffels M, van Dijk V, Alipour A, Chaldoupi S J Interv Card Electrophysiol. 2022; 65(2):471-480.

PMID: 35604577 PMC: 9640466. DOI: 10.1007/s10840-022-01249-2.

References
1.
Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B . 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Europace. 2016; 18(11):1609-1678. DOI: 10.1093/europace/euw295. View

2.
Kuck K, Brugada J, Furnkranz A, Metzner A, Ouyang F, Chun K . Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation. N Engl J Med. 2016; 374(23):2235-45. DOI: 10.1056/NEJMoa1602014. View

3.
Luik A, Radzewitz A, Kieser M, Walter M, Bramlage P, Hormann P . Cryoballoon Versus Open Irrigated Radiofrequency Ablation in Patients With Paroxysmal Atrial Fibrillation: The Prospective, Randomized, Controlled, Noninferiority FreezeAF Study. Circulation. 2015; 132(14):1311-9. PMC: 4590523. DOI: 10.1161/CIRCULATIONAHA.115.016871. View

4.
Cardoso R, Mendirichaga R, Fernandes G, Healy C, Lambrakos L, Viles-Gonzalez J . Cryoballoon versus Radiofrequency Catheter Ablation in Atrial Fibrillation: A Meta-Analysis. J Cardiovasc Electrophysiol. 2016; 27(10):1151-1159. DOI: 10.1111/jce.13047. View

5.
Jourda F, Providencia R, Marijon E, Bouzeman A, Hireche H, Khoueiry Z . Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation-a prospective evaluation. Europace. 2014; 17(2):225-31. DOI: 10.1093/europace/euu215. View