» Articles » PMID: 32344713

Combined Long-Period Fiber Grating and Microcavity In-Line Mach-Zehnder Interferometer for Refractive Index Measurements with Limited Cross-Sensitivity

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2020 Apr 30
PMID 32344713
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

This work discusses sensing properties of a long-period grating (LPG) and microcavity in-line Mach-Zehnder interferometer (µIMZI) when both are induced in the same single-mode optical fiber. LPGs were either etched or nanocoated with aluminum oxide (AlO) to increase its refractive index (RI) sensitivity up to ≈2000 and 9000 nm/RIU, respectively. The µIMZI was machined using a femtosecond laser as a cylindrical cavity (d = 60 μm) in the center of the LPG. In transmission measurements for various RI in the cavity and around the LPG we observed two effects coming from the two independently working sensors. This dual operation had no significant impact on either of the devices in terms of their functional properties, especially in a lower RI range. Moreover, due to the properties of combined sensors two major effects can be distinguished-sensitivity to the RI of the volume and sensitivity to the RI at the surface. Considering also the negligible temperature sensitivity of the µIMZI, it makes the combination of LPG and µIMZI sensors a promising approach to limit cross-sensitivity or tackle simultaneous measurements of multiple effects with high efficiency and reliability.

Citing Articles

An All-Fiber Fabry-Pérot Sensor for Emulsion Concentration Measurements.

Pevec S, Kunavar J, Budinski V, Njegovec M, donlagic D Sensors (Basel). 2023; 23(4).

PMID: 36850505 PMC: 9967868. DOI: 10.3390/s23041905.


Long Period Grating Mach-Zehnder Interferometer Based Immunosensor with Temperature and Bulk Refractive Index Compensation.

Wu P, Liu L, Morgan S, Correia R, Korposh S Biosensors (Basel). 2022; 12(12).

PMID: 36551066 PMC: 9775309. DOI: 10.3390/bios12121099.


Label-Free and Reproducible Chemical Sensor Using the Vertical-Fluid-Array Induced Optical Fiber Long Period Grating (VIOLIN).

Hu D, Xu Z, Long J, Xiao P, Liang L, Sun L Sensors (Basel). 2020; 20(12).

PMID: 32560450 PMC: 7349261. DOI: 10.3390/s20123415.

References
1.
Smietana M, Koba M, Mikulic P, Bock W . Towards refractive index sensitivity of long-period gratings at level of tens of µm per refractive index unit: fiber cladding etching and nano-coating deposition. Opt Express. 2016; 24(11):11897-904. DOI: 10.1364/OE.24.011897. View

2.
Ran Z, Rao Y, Liu W, Liao X, Chiang K . Laser-micromachined Fabry-Perot optical fiber tip sensor for high-resolution temperature-independent measurement of refractive index. Opt Express. 2008; 16(3):2252-63. DOI: 10.1364/oe.16.002252. View

3.
Smietana M, Koba M, Mikulic P, Bock W . Measurements of reactive ion etching process effect using long-period fiber gratings. Opt Express. 2014; 22(5):5986-94. DOI: 10.1364/OE.22.005986. View

4.
Brzozowska E, Smietana M, Koba M, Gorska S, Pawlik K, Gamian A . Recognition of bacterial lipopolysaccharide using bacteriophage-adhesin-coated long-period gratings. Biosens Bioelectron. 2014; 67:93-9. DOI: 10.1016/j.bios.2014.07.027. View

5.
Smietana M, Bock W, Mikulic P, Ng A, Chinnappan R, Zourob M . Detection of bacteria using bacteriophages as recognition elements immobilized on long-period fiber gratings. Opt Express. 2011; 19(9):7971-8. DOI: 10.1364/OE.19.007971. View