» Articles » PMID: 32330109

The Validity of Urine Color As a Hydration Biomarker Within the General Adult Population and Athletes: A Systematic Review

Overview
Journal J Am Coll Nutr
Date 2020 Apr 25
PMID 32330109
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Frequent monitoring of hydration status may help to avoid the adverse effects of dehydration. Other than urine color assessment, hydration assessment methods are largely impractical for the general population and athletes to implement on a routine basis. Despite its widespread use, the validity of urine color as an indicator of hydration status has not been systematically evaluated. The objective of this systematic review is to determine the validity of urine color evaluation as a hydration status assessment method in the general adult population, older adults, and athletes. Using the PRISMA guidelines, electronic databases were searched to identify original research articles of all study design types for inclusion. Of the 424 articles screened, 10 met inclusion criteria. Most studies compared urine color to either urinary specific gravity or urine osmolality, and reported significant associations (r) ranging from 0.40 to 0.93. Lower correlations were noted in studies of adults aged >60 years. Studies generally reported a high sensitivity of urine color as a diagnostic tool for detecting dehydration and supported the ability of this method to distinguish across categories of hydration status. Research is needed to determine if clinicians, patients, and clients can accurately utilize this method in clinical and real-world settings. Future research is also needed to extend these findings to other populations, such as children.Key teaching pointsInadequate hydration can lead to impairments in physical performance and cognitive function.Methods used to assess hydration status include plasma/serum osmolality, urinary specific gravity (USG), urine osmolality (Uosm), change in body weight, urine volume, and urine color.Urine color assessment is a practical method that is routinely used in clinical, athletic, and other settings. The validity of this method has not been systemically evaluated.Available research was limited to 10 articles.Validity of this method was generally supported; however, research has not investigated the validity of this method by clinicians, patients and clients.

Citing Articles

Seasonal fluctuation of total water intake and hydration status among young men and women: a prospective cohort study.

Zhang J, Zhang N, Lu J, Liu S, Lin Y, Ma G Front Nutr. 2025; 11:1463501.

PMID: 39949867 PMC: 11821506. DOI: 10.3389/fnut.2024.1463501.


Validity between dual-energy x-ray absorptiometry and bioelectrical impedance for segmental fat analysis and a novel low-cost model developed using anthropometry in young adults.

Mecherques-Carini M, Albaladejo-Saura M, Esparza-Ros F, Baglietto N, Vaquero-Cristobal R J Transl Med. 2025; 23(1):40.

PMID: 39794794 PMC: 11720347. DOI: 10.1186/s12967-024-06062-1.


Criterion-related validity and reliability of the standing long jump test in adults: The Adult-Fit project.

Marin-Jimenez N, Perez-Bey A, Cruz-Leon C, Conde-Caveda J, Segura-Jimenez V, Castro-Pinero J Eur J Sport Sci. 2024; 24(9):1379-1392.

PMID: 39167610 PMC: 11369318. DOI: 10.1002/ejsc.12182.


Hydration status in adults with metabolic disorders in relation to socioeconomic, lifestyle and health factors.

Frackiewicz J, Ciecierska A, Bialkowska A, Drywien M, Hamulka J PLoS One. 2024; 19(7):e0305540.

PMID: 38968180 PMC: 11226131. DOI: 10.1371/journal.pone.0305540.


Validity and agreement between dual-energy X-ray absorptiometry, anthropometry and bioelectrical impedance in the estimation of fat mass in young adults.

Mecherques-Carini M, Albaladejo-Saura M, Vaquero-Cristobal R, Baglietto N, Esparza-Ros F Front Nutr. 2024; 11:1421950.

PMID: 38919386 PMC: 11198126. DOI: 10.3389/fnut.2024.1421950.