» Articles » PMID: 32304487

Surface Profiles of New-generation IOLs with Improved Intermediate Vision

Overview
Specialty Ophthalmology
Date 2020 Apr 19
PMID 32304487
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate the surface profile of different new-generation intraocular lenses (IOLs) designed to improve intermediate vision.

Setting: Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy.

Design: Prospective experimental laboratory study.

Methods: One higher-order aspheric monofocal IOL (Tecnis Eyhance ICB00) and 2 extended depth-of-focus (EDOF) IOLs (Tecnis Symfony ZXR00, Mini Well Ready) were examined and compared with monofocal IOLs with the same platform (Sensar AAB00, Tecnis ZCB00, Mini 4 Ready) using contact profilometry. Raw profiles were obtained and compared. The best-fit circle was then subtracted from each raw profile to highlight differences.

Results: The new higher-order aspheric IOL presented a peculiar profile, which appeared similar to the conventional monofocal IOL based on the same platform, with just minimal differences in the central design. One of the EDOF IOLs showed a diffractive design. The EDOF IOL based on spherical aberration presented a central steepening surrounded by a symmetric lateral change in depths.

Conclusions: Improved intermediate vision can be achieved by means of different optic designs. Unlike the traditional EDOF and multifocal IOLs based on a diffractive design, the profiles of new-generation IOLs are characterized by smooth and progressive changes of the superficial geometry.

Citing Articles

Comparison of Short-Term Clinical Outcomes After Implantation of Two Monofocal, Aspheric Intraocular Lenses.

Han J, Lee Y, Park N, Lee C, Jeon Y, Lee H Diagnostics (Basel). 2025; 14(24.

PMID: 39767223 PMC: 11674912. DOI: 10.3390/diagnostics14242862.


A comparative study of mini-monovision, crossed mini-monovision, and emmetropia with enhanced monofocal intraocular lenses.

Fujita Y, Nomura Y, Itami E, Oshika T Sci Rep. 2025; 15(1):916.

PMID: 39762240 PMC: 11704214. DOI: 10.1038/s41598-024-80663-0.


Visual Outcomes and Patient Satisfaction of Enhanced Monofocal Intraocular Lens in Phacovitrectomy for Idiopathic Epiretinal Membrane.

Choi J, Won Y, Lee S, Kang S, Lim D Bioengineering (Basel). 2024; 11(9).

PMID: 39329681 PMC: 11428223. DOI: 10.3390/bioengineering11090939.


Analysis of the optical performance of intraocular lenses using profilometric measurements.

Miret J, Camps V, Garcia C, Caballero M, Gonzalez-Leal J Graefes Arch Clin Exp Ophthalmol. 2024; 263(2):451-465.

PMID: 39287656 PMC: 11868146. DOI: 10.1007/s00417-024-06628-1.


Functional Design Analysis of Two Current Extended-Depth-of-Focus Intraocular Lenses.

Mendroch D, Oberheide U, Altmeyer S Transl Vis Sci Technol. 2024; 13(8):33.