Abstract

We set out to investigate the interference factors that led to false-positive novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgM detection results using gold immunochromatography assay (GICA) and enzyme-linked immunosorbent assay (ELISA) and the corresponding solutions. GICA and ELISA were used to detect SARS-CoV-2 IgM in 86 serum samples, including 5 influenza A virus (Flu A) IgM-positive sera, 5 influenza B virus (Flu B) IgM-positive sera, 5 IgM-positive sera, 5 IgM-positive sera, 6 sera of HIV infection patients, 36 rheumatoid factor IgM (RF-IgM)-positive sera, 5 sera from hypertensive patients, 5 sera from diabetes mellitus patients, and 14 sera from novel coronavirus infection disease 19 (COVID-19) patients. The interference factors causing false-positive reactivity with the two methods were analyzed, and the urea dissociation test was employed to dissociate the SARS-CoV-2 IgM-positive serum using the best dissociation concentration. The two methods detected positive SARS-CoV-2 IgM in 22 mid-to-high-level-RF-IgM-positive sera and 14 sera from COVID-19 patients; the other 50 sera were negative. At a urea dissociation concentration of 6 mol/liter, SARS-CoV-2 IgM results were positive in 1 mid-to-high-level-RF-IgM-positive serum and in 14 COVID-19 patient sera detected using GICA. At a urea dissociation concentration of 4 mol/liter and with affinity index (AI) levels lower than 0.371 set to negative, SARS-CoV-2 IgM results were positive in 3 mid-to-high-level-RF-IgM-positive sera and in 14 COVID-19 patient sera detected using ELISA. The presence of RF-IgM at mid-to-high levels could lead to false-positive reactivity of SARS-CoV-2 IgM detected using GICA and ELISA, and urea dissociation tests would be helpful in reducing SARS-CoV-2 IgM false-positive results.

Citing Articles

A novel method for detecting SARS-CoV-2 IgM and IgG based on the gold immune chromatography assay.

Yao X, Xu H, Du Q, Lu X, Wang Q Sci Rep. 2025; 15(1):4995.

PMID: 39929938 PMC: 11811196. DOI: 10.1038/s41598-025-89012-1.


Receptor Binding Domain-Specific B Cell Memory Responses Among Individuals Vaccinated Against SARS-CoV-2.

Athavale A, Gaur A, Ahmed N, Subramaniam A, Dandotiya J, Raj S Vaccines (Basel). 2025; 12(12.

PMID: 39772064 PMC: 11680197. DOI: 10.3390/vaccines12121396.


Overcoming Limited Access to Virus Infection Rapid Testing: Development of a Lateral Flow Test for SARS-CoV-2 with Locally Available Resources.

Peri Ibanez E, Mazzeo A, Silva C, Juncos M, Costa Navarro G, Pallares H Biosensors (Basel). 2024; 14(9).

PMID: 39329791 PMC: 11431090. DOI: 10.3390/bios14090416.


Vertical transmission of SARS-CoV-2 delta-variant in a preterm infant.

Zia M, Kumar K, Gamma E, Shakeel F, Hanna I, Lin X BMC Infect Dis. 2024; 24(1):537.

PMID: 38807052 PMC: 11134764. DOI: 10.1186/s12879-024-09420-y.


Investigating the diagnostic and prognostic value of anti-SARS-CoV-2 Spike IgG/IgM ELISA tests in patients infected with coronavirus Delta variant.

Pouladzadeh M, Hosseinzadeh M, Khedri R, Choghakabodi P, Amini P, Bavani A Infez Med. 2024; 32(1):25-36.

PMID: 38456030 PMC: 10917556. DOI: 10.53854/liim-3201-4.


References
1.
Poussin M, Fuentes V, Corbel C, Prin L, Eb F, ORFILA J . Capture-ELISA: a new assay for the detection of immunoglobulin M isotype antibodies using Chlamydia trachomatis antigen. J Immunol Methods. 1997; 204(1):1-12. DOI: 10.1016/s0022-1759(97)00014-8. View

2.
Bobic B, Klun I, Vujanic M, Nikolic A, Ivovic V, Zivkovic T . Comparative evaluation of three commercial Toxoplasma-specific IgG antibody avidity tests and significance in different clinical settings. J Med Microbiol. 2009; 58(Pt 3):358-364. DOI: 10.1099/jmm.0.006668-0. View

3.
Chen J, Meng H, An Y, Liu J, Yang R, Qu L . A fluorescent nanosphere-based immunochromatography test strip for ultrasensitive and point-of-care detection of tetanus antibody in human serum. Anal Bioanal Chem. 2019; 412(5):1151-1158. DOI: 10.1007/s00216-019-02343-7. View

4.
Pruksaphon K, Intaramat A, Ratanabanangkoon K, Nosanchuk J, Vanittanakom N, Youngchim S . Diagnostic laboratory immunology for talaromycosis (penicilliosis): review from the bench-top techniques to the point-of-care testing. Diagn Microbiol Infect Dis. 2019; 96(3):114959. DOI: 10.1016/j.diagmicrobio.2019.114959. View

5.
Wu P, Hao X, Lau E, Wong J, Leung K, Wu J . Real-time tentative assessment of the epidemiological characteristics of novel coronavirus infections in Wuhan, China, as at 22 January 2020. Euro Surveill. 2020; 25(3). PMC: 6988272. DOI: 10.2807/1560-7917.ES.2020.25.3.2000044. View