» Articles » PMID: 31867701

A Fluorescent Nanosphere-based Immunochromatography Test Strip for Ultrasensitive and Point-of-care Detection of Tetanus Antibody in Human Serum

Overview
Specialty Chemistry
Date 2019 Dec 24
PMID 31867701
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Tetanus still possesses a high infection risk and leads a number of human deaths in poor nations. Point-of-care and ultrasensitive detection of tetanus antibody levels in serum is the key to decrease the risk of tetanus infection and improve the health of people. In this work, by using ultra bright fluorescent nanospheres (FNs) and portable lateral flow test strip (LFTS), a point-of-care and ultrasensitive sensing method has been developed for the detection of tetanus antibodies in human serum. This assay works quite well for tetanus antibodies in the concentration range from 0.0002 to 0.0220 IU/mL with a low detection limit of 0.00011 IU/mL, which is 100-fold lower than conventional gold-based LFTSs. The high sensitivity makes this method suitable for use to detect the low-abundant target in real samples. Besides, this cost-effective FN-based LFTS assay possesses good selectivity, high accuracy, and satisfactory reliability, which holds great potential as a robust candidate for routine medical diagnosis and rapid home testing. Graphical abstract.

Citing Articles

Establishment of a multi-line immunochromatography based on magnetic nanoparticles for simultaneous screening of multiple biomarkers.

Shen L, Peng T, Dong J, Liang Z, Si J, Ye H Anal Bioanal Chem. 2024; 416(22):4823-4831.

PMID: 38981912 DOI: 10.1007/s00216-024-05432-4.


Fluorescent immunochromatographic test strip for therapeutic drug monitoring of methotrexate with high sensitivity and wide dynamic range.

Zhu Z, Zhang Y, Xue J, Kong J, Huang L, Ouyang H Mikrochim Acta. 2023; 190(9):342.

PMID: 37540283 DOI: 10.1007/s00604-023-05917-6.


Recent advances in immunoassay technologies for the detection of human coronavirus infections.

Wang D, Chen Y, Xiang S, Hu H, Zhan Y, Yu Y Front Cell Infect Microbiol. 2023; 12:1040248.

PMID: 36683684 PMC: 9845787. DOI: 10.3389/fcimb.2022.1040248.


Fluorescent hollow ZrO@CdTe nanoparticles-based lateral flow assay for simultaneous detection of C-reactive protein and troponin T.

Liu X, Ren X, Chen L, Zou J, Li T, Tan L Mikrochim Acta. 2021; 188(6):209.

PMID: 34047819 DOI: 10.1007/s00604-021-04865-3.


Developing an integrated microfluidic and miniaturized electrochemical biosensor for point of care determination of glucose in human plasma samples.

Azimi S, Farahani A, Docoslis A, Vahdatifar S Anal Bioanal Chem. 2021; 413(5):1441-1452.

PMID: 33388843 DOI: 10.1007/s00216-020-03108-3.