» Articles » PMID: 32269772

Fractional Exhaled Nitric Oxide (FENO) in the Management of Asthma: a Position Paper of the Italian Respiratory Society (SIP/IRS) and Italian Society of Allergy, Asthma and Clinical Immunology (SIAAIC)

Abstract

Asthma prevalence in Italy is on the rise and is estimated to be over 6% of the general population. The diagnosis of asthma can be challenging and elusive, especially in children and the last two decades has brought evidences that asthma is not a single disease but consists of various phenotypes. Symptoms can be underestimated by the patient or underreported to the clinician and physical signs can be scanty. Usual objective measures, like spirometry, are necessary but sometimes not significant. Despite proper treatment, asthma can be a very severe condition (even leading to death), however new drugs have recently become available which can be very effective in its control. Since asthma is currently thought to be caused by inflammation, a direct measure of the latter can be of paramount importance. For this purpose, the measurement of Fractional Exhaled Nitric Oxide (FE) has been used since the early years of the current century as a non-invasive, easy-to-assess tool useful for diagnosing and managing asthma. This SIP-IRS/SIAAIC Position Paper is a narrative review which summarizes the evidence behind the usefulness of FE in the diagnosis, management and phenotypization of asthma.

Citing Articles

Highly Efficient UV-Activated TiO/SnO Surface Nano-matrix Gas Sensor: Enhancing Stability for ppb-Level NO Detection at Room Temperature.

Deb M, Ghossoub Y, Noel L, Li P, Tsai H, Soppera O ACS Appl Mater Interfaces. 2025; 17(9):14670-14681.

PMID: 39970259 PMC: 11891840. DOI: 10.1021/acsami.4c19998.


Development of a new breath collection method for analyzing volatile organic compounds from intubated mouse models.

Taylor A, Blum S, Ball M, Birch O, Chou H, Greenwood J Biol Methods Protoc. 2024; 9(1):bpae087.

PMID: 39659672 PMC: 11631442. DOI: 10.1093/biomethods/bpae087.


A Review on Asthma and Allergy: Current Understanding on Molecular Perspectives.

Gohal G, Moni S, Bakkari M, Elmobark M J Clin Med. 2024; 13(19).

PMID: 39407835 PMC: 11476424. DOI: 10.3390/jcm13195775.


Relationship between fraction of exhaled nitric oxide and peripheral eosinophilia in asthma.

Afriyie-Mensah J, Domoyeri P, Antwi-Boasiako C, Aryee R, Dankwah G, Ntiamoah M Ann Med. 2024; 56(1):2382377.

PMID: 39051101 PMC: 11275527. DOI: 10.1080/07853890.2024.2382377.


House dust mite allergen avoidance strategies for the treatment of allergic asthma: A hypothesis-generating meta-analysis.

van Boven F, Braunstahl G, Arends L, van Maaren M, Bramer W, van Wijk R World Allergy Organ J. 2024; 17(6):100919.

PMID: 38966606 PMC: 11223119. DOI: 10.1016/j.waojou.2024.100919.


References
1.
Arnold R, Layton A, Massanari M . Cost impact of monitoring exhaled nitric oxide in asthma management. Allergy Asthma Proc. 2018; 39(5):338-344. DOI: 10.2500/aap.2018.39.4165. View

2.
Price D, Bosnic-Anticevich S, Pavord I, Roche N, Halpin D, Bjermer L . Association of elevated fractional exhaled nitric oxide concentration and blood eosinophil count with severe asthma exacerbations. Clin Transl Allergy. 2019; 9:41. PMC: 6702739. DOI: 10.1186/s13601-019-0282-7. View

3.
Jackson D, Virnig C, Gangnon R, Evans M, Roberg K, Anderson E . Fractional exhaled nitric oxide measurements are most closely associated with allergic sensitization in school-age children. J Allergy Clin Immunol. 2009; 124(5):949-53. PMC: 2784153. DOI: 10.1016/j.jaci.2009.07.024. View

4.
Travers J, Marsh S, Aldington S, Williams M, Shirtcliffe P, Pritchard A . Reference ranges for exhaled nitric oxide derived from a random community survey of adults. Am J Respir Crit Care Med. 2007; 176(3):238-42. DOI: 10.1164/rccm.200609-1346OC. View

5.
Michils A, Baldassarre S, Van Muylem A . Exhaled nitric oxide and asthma control: a longitudinal study in unselected patients. Eur Respir J. 2007; 31(3):539-46. DOI: 10.1183/09031936.00020407. View