A Microcomputer-based System for Automated EEG Collection and Scoring of Behavioral State in Cats
Overview
Authors
Affiliations
A data acquisition and analysis system based on an Apple II microcomputer has been developed for use in sleep studies in the adult cat. The system reliably counts delta, spindle, and EMG waveforms, PGO waves, and REMs using amplitude and frequency criteria. These data can be used to algorithmically score sleep-wake state with high reliability (greater than 90% agreement with manual scoring). This method allows for automatic and quantitative analysis of selected EEG waveforms and sleep-wake states with less expense, more time savings, and greater convenience than manual scoring.
Automatic detection of periods of slow wave sleep based on intracranial depth electrode recordings.
Reed C, Birch K, Kaminski J, Sullivan S, Chung J, Mamelak A J Neurosci Methods. 2017; 282:1-8.
PMID: 28238858 PMC: 5455770. DOI: 10.1016/j.jneumeth.2017.02.009.
FASTER: an unsupervised fully automated sleep staging method for mice.
Sunagawa G, Sei H, Shimba S, Urade Y, Ueda H Genes Cells. 2013; 18(6):502-18.
PMID: 23621645 PMC: 3712478. DOI: 10.1111/gtc.12053.
Sinha R J Med Syst. 2008; 32(4):291-9.
PMID: 18619093 DOI: 10.1007/s10916-008-9134-z.
EEG power spectrum and neural network based sleep-hypnogram analysis for a model of heat stress.
Sinha R J Clin Monit Comput. 2008; 22(4):261-8.
PMID: 18521711 DOI: 10.1007/s10877-008-9128-x.
Quattrochi J, Bazalakova M, Hobson J Brain Res Mol Brain Res. 2005; 136(1-2):164-76.
PMID: 15893601 PMC: 1570022. DOI: 10.1016/j.molbrainres.2005.02.012.