» Articles » PMID: 32160925

Standardized Image Interpretation and Post-processing in Cardiovascular Magnetic Resonance - 2020 Update : Society for Cardiovascular Magnetic Resonance (SCMR): Board of Trustees Task Force on Standardized Post-Processing

Abstract

With mounting data on its accuracy and prognostic value, cardiovascular magnetic resonance (CMR) is becoming an increasingly important diagnostic tool with growing utility in clinical routine. Given its versatility and wide range of quantitative parameters, however, agreement on specific standards for the interpretation and post-processing of CMR studies is required to ensure consistent quality and reproducibility of CMR reports. This document addresses this need by providing consensus recommendations developed by the Task Force for Post-Processing of the Society for Cardiovascular Magnetic Resonance (SCMR). The aim of the Task Force is to recommend requirements and standards for image interpretation and post-processing enabling qualitative and quantitative evaluation of CMR images. Furthermore, pitfalls of CMR image analysis are discussed where appropriate. It is an update of the original recommendations published 2013.

Citing Articles

Quantitative perfusion by cardiac magnetic resonance imaging reveals compromised myocardial perfusion in patients with angina with non-obstructive coronary artery disease.

Vink C, Borodzicz-Jazdzyk S, de Jong E, Woudstra J, van de Hoef T, Chamuleau S Clin Res Cardiol. 2025; .

PMID: 39966158 DOI: 10.1007/s00392-025-02606-7.


Investigating the Use of Generative Adversarial Networks-Based Deep Learning for Reducing Motion Artifacts in Cardiac Magnetic Resonance.

Ma Z, Zhu Y, Zhang X, Zhao Y, Zheng W, Yuan S J Multidiscip Healthc. 2025; 18:787-799.

PMID: 39963324 PMC: 11830935. DOI: 10.2147/JMDH.S492163.


Association of body composition with left ventricular remodeling and outcomes in diabetic heart failure with reduced ejection fraction: assessment of sarcopenic obesity using cardiac MRI.

Shi K, Zhang G, Xu R, Li X, Jiang L, Gao Y Cardiovasc Diabetol. 2025; 24(1):79.

PMID: 39962525 PMC: 11834579. DOI: 10.1186/s12933-025-02639-2.


Long-term cardiac MRI follow up of MANTICORE (Multidisciplinary Approach to Novel Therapies in Cardio-Oncology REsearch).

Labib D, Haykowsky M, Sonnex E, Mackey J, Thompson R, Paterson D Cardiooncology. 2025; 11(1):13.

PMID: 39923094 PMC: 11806551. DOI: 10.1186/s40959-025-00313-w.


Prognostic Value of Myocardial Parametric Mapping in Patients with Acute Myocarditis: A Retrospective Study.

Wang Y, Duan X, Zhu L, Xu J, Zhou D, Yang W Radiol Cardiothorac Imaging. 2025; 7(1):e240125.

PMID: 39912725 PMC: 11880863. DOI: 10.1148/ryct.240125.


References
1.
Hsu L, Jacobs M, Benovoy M, Ta A, Conn H, Winkler S . Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance. JACC Cardiovasc Imaging. 2018; 11(5):697-707. PMC: 8760891. DOI: 10.1016/j.jcmg.2018.01.005. View

2.
McCrohon J, Moon J, Prasad S, McKenna W, Lorenz C, Coats A . Differentiation of heart failure related to dilated cardiomyopathy and coronary artery disease using gadolinium-enhanced cardiovascular magnetic resonance. Circulation. 2003; 108(1):54-9. DOI: 10.1161/01.CIR.0000078641.19365.4C. View

3.
Kawel-Boehm N, Maceira A, Valsangiacomo-Buechel E, Vogel-Claussen J, Turkbey E, Williams R . Normal values for cardiovascular magnetic resonance in adults and children. J Cardiovasc Magn Reson. 2015; 17:29. PMC: 4403942. DOI: 10.1186/s12968-015-0111-7. View

4.
Mohiaddin R, Kilner P, Rees S, LONGMORE D . Magnetic resonance volume flow and jet velocity mapping in aortic coarctation. J Am Coll Cardiol. 1993; 22(5):1515-21. DOI: 10.1016/0735-1097(93)90565-i. View

5.
Thiele H, Paetsch I, Schnackenburg B, Bornstedt A, Grebe O, Wellnhofer E . Improved accuracy of quantitative assessment of left ventricular volume and ejection fraction by geometric models with steady-state free precession. J Cardiovasc Magn Reson. 2002; 4(3):327-39. DOI: 10.1081/jcmr-120013298. View