» Articles » PMID: 32154970

Dynamic 2D and 3D Mapping of Hyperpolarized Pyruvate to Lactate Conversion in Vivo with Efficient Multi-echo Balanced Steady-state Free Precession at 3 T

Abstract

The aim of this study was to acquire the transient MRI signal of hyperpolarized tracers and their metabolites efficiently, for which specialized imaging sequences are required. In this work, a multi-echo balanced steady-state free precession (me-bSSFP) sequence with Iterative Decomposition with Echo Asymmetry and Least squares estimation (IDEAL) reconstruction was implemented on a clinical 3 T positron-emission tomography/MRI system for fast 2D and 3D metabolic imaging. Simulations were conducted to obtain signal-efficient sequence protocols for the metabolic imaging of hyperpolarized biomolecules. The sequence was applied in vitro and in vivo for probing the enzymatic exchange of hyperpolarized [1- C]pyruvate and [1- C]lactate. Chemical shift resolution was achieved using a least-square, iterative chemical species separation algorithm in the reconstruction. In vitro, metabolic conversion rate measurements from me-bSSFP were compared with NMR spectroscopy and free induction decay-chemical shift imaging (FID-CSI). In vivo, a rat MAT-B-III tumor model was imaged with me-bSSFP and FID-CSI. 2D metabolite maps of [1- C]pyruvate and [1- C]lactate acquired with me-bSSFP showed the same spatial distributions as FID-CSI. The pyruvate-lactate conversion kinetics measured with me-bSSFP and NMR corresponded well. Dynamic 2D metabolite mapping with me-bSSFP enabled the acquisition of up to 420 time frames (scan time: 180-350 ms/frame) before the hyperpolarized [1- C]pyruvate was relaxed below noise level. 3D metabolite mapping with a large field of view (180 × 180 × 48 mm ) and high spatial resolution (5.6 × 5.6 × 2 mm ) was conducted with me-bSSFP in a scan time of 8.2 seconds. It was concluded that Me-bSSFP improves the spatial and temporal resolution for metabolic imaging of hyperpolarized [1- C]pyruvate and [1- C]lactate compared with either of the FID-CSI or EPSI methods reported at 3 T, providing new possibilities for clinical and preclinical applications.

Citing Articles

First-in-human in-vivo depiction of paraganglioma metabolism by hyperpolarised C-magnetic resonance.

Chowdhury R, Moorthy M, Smith L, Mueller C, Gong F, Rogers H BJR Case Rep. 2023; 9(6):20220089.

PMID: 37928705 PMC: 10621573. DOI: 10.1259/bjrcr.20220089.


Hyperpolarized Carbon 13 MRI: Clinical Applications and Future Directions in Oncology.

Deen S, Rooney C, Shinozaki A, McGing J, Grist J, Tyler D Radiol Imaging Cancer. 2023; 5(5):e230005.

PMID: 37682052 PMC: 10546364. DOI: 10.1148/rycan.230005.


Nitrogen-15 dynamic nuclear polarization of nicotinamide derivatives in biocompatible solutions.

Peters J, Brahms A, Janicaud V, Anikeeva M, Peschke E, Ellermann F Sci Adv. 2023; 9(34):eadd3643.

PMID: 37611105 PMC: 10446501. DOI: 10.1126/sciadv.add3643.


Catalyst-Free Aqueous Hyperpolarized [1-C]Pyruvate Obtained by Re-Dissolution Signal Amplification by Reversible Exchange.

Schmidt A, de Maissin H, Adelabu I, Nantogma S, Ettedgui J, TomHon P ACS Sens. 2022; 7(11):3430-3439.

PMID: 36379005 PMC: 9983023. DOI: 10.1021/acssensors.2c01715.


Quantification of Prostate Cancer Metabolism Using 3D Multiecho bSSFP and Hyperpolarized [1- C] Pyruvate: Metabolism Differs Between Tumors of the Same Gleason Grade.

Chowdhury R, Mueller C, Smith L, Gong F, Papoutsaki M, Rogers H J Magn Reson Imaging. 2022; 57(6):1865-1875.

PMID: 36315000 PMC: 10946772. DOI: 10.1002/jmri.28467.