» Articles » PMID: 32138368

The Impact of Implant-Abutment Connection on Clinical Outcomes and Microbial Colonization: A Narrative Review

Overview
Publisher MDPI
Date 2020 Mar 7
PMID 32138368
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Osseointegration are often suffering from oral conditions, especially, the micro gap at the implant-abutment connection represents a site for bacterial plaque aggregation, leading to increased inflammatory cells and causing peri-implantitis.

Aim: The aim of this narrative review was to describe the different kinds of implant-abutment connections and their ability to reduce bacterial leakage and thus prevent peri-implantitis.

Materials And Methods: The following databases were consulted: Pubmed, Scopus, Cochrane Library, and Research gate and a total of 528 articles were found. After reading the abstract and titles, 473 items were excluded. The remaining articles (n = 55) were assessed for full-text eligibility. Thirty-three studies were included in the review.

Results And Conclusions: We selected 22 clinical trials and 11 reviews, examining a total sample of 2110 implants. From the review, it was clear that there exists a relationship between the implant-abutment interface and bacterial leakage. All the connections presented an amount of micro-gap and bacterial micro-leakage, though conical and mixed connection systems seemed to behave better. Moreover, both connections seemed to have a better load distribution and the mixed system also had anti-rotational properties which are very useful during the positioning of the prosthesis.

Citing Articles

Clinical and radiographic outcomes of extra-short implants (≤ 6 mm) in the posterior atrophic jaws: a retrospective cohort study.

Sivolella S, Giovannini S, Berberi J, Stocchero M, Brunello G Int J Implant Dent. 2025; 11(1):4.

PMID: 39832106 PMC: 11747052. DOI: 10.1186/s40729-025-00592-z.


Evaluating the microgap and sealing capability in four implant systems with different interlockings under different tightening torques: an study.

Mousa M, Alshubrmi H, Issrani R, Alzarea B J Adv Prosthodont. 2025; 16(6):336-347.

PMID: 39803384 PMC: 11711449. DOI: 10.4047/jap.2024.16.6.336.


A New Multi-Axial Functional Stress Analysis Assessing the Longevity of a Ti-6Al-4V Dental Implant Abutment Screw.

Naguib G, Abougazia A, Al-Turki L, Mously H, Hashem A, Mira A Biomimetics (Basel). 2024; 9(11).

PMID: 39590261 PMC: 11591605. DOI: 10.3390/biomimetics9110689.


Influence of Framework Material and Abutment Configuration on Fatigue Performance in Dental Implant Systems: A Finite Element Analysis.

Erdogdu M, Demirel M, Mohammadi R, Guntekin N, Ghanbarzadeh Chaleshtori M Medicina (Kaunas). 2024; 60(9).

PMID: 39336504 PMC: 11433853. DOI: 10.3390/medicina60091463.


A Comparative Analysis of the Efficacy of Bacterial Lysate versus Antibiotic Therapy in the Treatment of Experimental Peri-Implantitis in Rats.

Ancuta D, Alexandru D, tucureanu C, Coman C Microorganisms. 2024; 12(8).

PMID: 39203379 PMC: 11356466. DOI: 10.3390/microorganisms12081537.


References
1.
Gherlone E, Cappare P, Pasciuta R, Grusovin M, Mancini N, Burioni R . Evaluation of resistance against bacterial microleakage of a new conical implant-abutment connection versus conventional connections: an in vitro study. New Microbiol. 2016; 39(1):49-56. View

2.
Ugurel C, Steiner M, Isik-Ozkol G, Kutay O, Kern M . Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections. Clin Oral Implants Res. 2013; 26(2):137-42. DOI: 10.1111/clr.12303. View

3.
Pardal-Pelaez B, Montero J . Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review. J Clin Exp Dent. 2018; 9(11):e1355-e1361. PMC: 5741850. DOI: 10.4317/jced.54374. View

4.
He Y, Fok A, Aparicio C, Teng W . Contact analysis of gap formation at dental implant-abutment interface under oblique loading: A numerical-experimental study. Clin Implant Dent Relat Res. 2019; 21(4):741-752. DOI: 10.1111/cid.12792. View

5.
Andreasi Bassi M, Lopez M, Confalone L, Gaudio R, Lombardo L, Lauritano D . Clinical outcome of a two-piece implant system with an internal hexagonal connection: a prospective study. J Biol Regul Homeost Agents. 2016; 30(2 Suppl 1):7-12. View