» Articles » PMID: 3207891

In Vivo Recovery and Half-life Time of a Steam-treated Factor IX Concentrate in Hemophilia B Patients. The Influence of Reagents and Standards

Overview
Journal Blut
Specialty Hematology
Date 1988 Dec 1
PMID 3207891
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Factor IX (FIX) recovery and half-life was measured in ten hemophilia B patients under standardized conditions. Each patient received a steam-treated high-purity factor IX concentrate at a dose of 19-39 U/kg body weight. FIX activity was determined using a one-stage assay, which was calibrated against the international concentrate standard (reagents from Immuno, Heidelberg). The in vivo recovery ranged from 24% to 53% (mean value 37.7%) and the half-disappearance time (HDT) from 8-30 h (mean 16.7 h). In four of the ten patients, the distribution and elimination half-lives were estimated and ranged from 0.3 h to 3.9 h (mean 1.4 h) and from 28.6 h to 39.7 h (mean 33.1 h), respectively. In six patients FIX was redetermined using a different FIX deficient plasma and a plasma standard (reagents from Merz & Dade, Munich, FRG). Recoveries and HDT based on the results obtained with this method were significantly higher (68.2% vs 39.7%; p less than 0.05), and longer (14.8 h vs 10.6 h; p less than 0.05), respectively. FIX activity was also measured by both assay systems in 100 healthy subjects (50 males, 50 females). The reagents from Immuno yielded a mean value of 0.77 U/ml, while the mean FIX activity utilizing standards and reagents from Merz & Dade was 1.11 U/ml (p less than 0.000001). The coefficient of correlation between the FIX activity measurements, as determined in 100 healthy subjects and 6 hemophilia B patients using the different test systems, was r = 0.9 (N = 159; y = 0.08 +/- 1.3* chi; p less than 0.001). Our data suggest that recovery and HDT of factor IX concentrate strongly depend on the assay and calibration conditions and that an international FIX activity plasma standard is urgently required.

Citing Articles

Comparative field study: impact of laboratory assay variability on the assessment of recombinant factor IX Fc fusion protein (rFIXFc) activity.

Sommer J, Buyue Y, Bardan S, Peters R, Jiang H, Kamphaus G Thromb Haemost. 2014; 112(5):932-40.

PMID: 25144892 PMC: 6374931. DOI: 10.1160/TH13-11-0971.


Secondary prophylaxis with factor IX concentrates: continuous infusion.

Morfini M Blood Transfus. 2008; 6 Suppl 2:s21-5.

PMID: 19105506 PMC: 2652220. DOI: 10.2450/2008.0033-08.


Pharmacokinetics of factor IX in patients with haemophilia B. Methodological aspects and physiological interpretation.

Bjorkman S, Carlsson M, Berntorp E Eur J Clin Pharmacol. 1994; 46(4):325-32.

PMID: 7957517 DOI: 10.1007/BF00194400.

References
1.
HOAG M, Johnson F, Robinson J, AGGELER P . Treatment of hemophilia B with a new clotting-factor concentrate. N Engl J Med. 1969; 280(11):581-6. DOI: 10.1056/NEJM196903132801103. View

2.
Heldebrant C, Gomperts E, Kasper C, McDougal J, Friedman A, Hwang D . Evaluation of two viral inactivation methods for the preparation of safer factor VIII and factor IX concentrates. Transfusion. 1985; 25(6):510-5. DOI: 10.1046/j.1537-2995.1985.25686071421.x. View

3.
Schimpf K, Mannucci P, Kreutz W, Brackmann H, Auerswald G, Ciavarella N . Absence of hepatitis after treatment with a pasteurized factor VIII concentrate in patients with hemophilia and no previous transfusions. N Engl J Med. 1987; 316(15):918-22. DOI: 10.1056/NEJM198704093161505. View

4.
Mannucci P, Zanetti A, Colombo M . Prospective study of hepatitis after factor VIII concentrate exposed to hot vapour. Br J Haematol. 1988; 68(4):427-30. DOI: 10.1111/j.1365-2141.1988.tb04230.x. View

5.
Noe D, Bell W, Ness P, Levin J . Plasma clearance rates of coagulation factors VIII and IX in factor-deficient individuals. Blood. 1986; 67(4):969-72. View