» Articles » PMID: 32047863

Investigating Sources of Inaccuracy in Wearable Optical Heart Rate Sensors

Overview
Journal NPJ Digit Med
Date 2020 Feb 13
PMID 32047863
Citations 194
Authors
Affiliations
Soon will be listed here.
Abstract

As wearable technologies are being increasingly used for clinical research and healthcare, it is critical to understand their accuracy and determine how measurement errors may affect research conclusions and impact healthcare decision-making. Accuracy of wearable technologies has been a hotly debated topic in both the research and popular science literature. Currently, wearable technology companies are responsible for assessing and reporting the accuracy of their products, but little information about the evaluation method is made publicly available. Heart rate measurements from wearables are derived from photoplethysmography (PPG), an optical method for measuring changes in blood volume under the skin. Potential inaccuracies in PPG stem from three major areas, includes (1) diverse skin types, (2) motion artifacts, and (3) signal crossover. To date, no study has systematically explored the accuracy of wearables across the full range of skin tones. Here, we explored heart rate and PPG data from consumer- and research-grade wearables under multiple circumstances to test whether and to what extent these inaccuracies exist. We saw no statistically significant difference in accuracy across skin tones, but we saw significant differences between devices, and between activity types, notably, that absolute error during activity was, on average, 30% higher than during rest. Our conclusions indicate that different wearables are all reasonably accurate at resting and prolonged elevated heart rate, but that differences exist between devices in responding to changes in activity. This has implications for researchers, clinicians, and consumers in drawing study conclusions, combining study results, and making health-related decisions using these devices.

Citing Articles

Laboratory comparison of consumer-grade and research-established wearables for monitoring heart rate, body temperature, and physical acitivity in sub-Saharan Africa.

Mendt S, Zout G, Rabuffetti M, Gunga H, Bunker A, Barteit S Front Physiol. 2025; 16:1491401.

PMID: 40017799 PMC: 11865084. DOI: 10.3389/fphys.2025.1491401.


Wearable blood pressure sensors for cardiovascular monitoring and machine learning algorithms for blood pressure estimation.

Min S, An J, Lee J, Kim J, Joe D, Eom S Nat Rev Cardiol. 2025; .

PMID: 39966649 DOI: 10.1038/s41569-025-01127-0.


Wearables and Atrial Fibrillation: Advances in Detection, Clinical Impact, Ethical Concerns, and Future Perspectives.

Francisco A, Pascoal C, Lamborne P, Morais H, Goncalves M Cureus. 2025; 17(1):e77404.

PMID: 39949464 PMC: 11822239. DOI: 10.7759/cureus.77404.


Validity of heart rate measurements in wrist-based monitors across skin tones during exercise.

Hung S, Serwa K, Rosenthal G, Eng J PLoS One. 2025; 20(2):e0318724.

PMID: 39928630 PMC: 11809914. DOI: 10.1371/journal.pone.0318724.


Quality in Question: Assessing the Accuracy of Four Heart Rate Wearables and the Implications for Psychophysiological Research.

Sinichi M, Gevonden M, Krabbendam L Psychophysiology. 2025; 62(2):e70004.

PMID: 39905563 PMC: 11794680. DOI: 10.1111/psyp.70004.


References
1.
Six Dijkstra M, Soer R, Bieleman A, McCraty R, Oosterveld F, Gross D . Exploring a 1-Minute Paced Deep-Breathing Measurement of Heart Rate Variability as Part of a Workers' Health Assessment. Appl Psychophysiol Biofeedback. 2018; 44(2):83-96. PMC: 6505487. DOI: 10.1007/s10484-018-9422-4. View

2.
Munos B, Baker P, Bot B, Crouthamel M, de Vries G, Ferguson I . Mobile health: the power of wearables, sensors, and apps to transform clinical trials. Ann N Y Acad Sci. 2016; 1375(1):3-18. DOI: 10.1111/nyas.13117. View

3.
Zonios G, Bykowski J, Kollias N . Skin melanin, hemoglobin, and light scattering properties can be quantitatively assessed in vivo using diffuse reflectance spectroscopy. J Invest Dermatol. 2002; 117(6):1452-7. DOI: 10.1046/j.0022-202x.2001.01577.x. View

4.
Sartor F, Gelissen J, van Dinther R, Roovers D, Papini G, Coppola G . Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients. BMC Sports Sci Med Rehabil. 2018; 10:10. PMC: 5984393. DOI: 10.1186/s13102-018-0098-0. View

5.
Ries A, Prewitt L, Johnson J . Skin color and ear oximetry. Chest. 1989; 96(2):287-90. DOI: 10.1378/chest.96.2.287. View