Infection Screening in Biofluids with Glucose Test Strips

Overview
Journal Anal Chem
Specialty Chemistry
Date 2020 Feb 11
PMID 32040916
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

The four glucosyl esters were synthesized and tested for the determination of infection enzyme leukocyte esterase (LE) in human synovial (joint) fluid and urine. The esters acted as LE substrates releasing glucose in a direct proportion to the activity of LE in a sample. The freed glucose was then detected by a coupled-enzyme assay at either a nitrogen-doped carbon nanotube (N-CNT) electrode or a commercial glucose test strip. The assays at the N-CNT electrode detected LE down to 0.81 nM (25 μg L) and showed the fastest kinetics (2.1 × 10 M s) for esters with the least crowded space around their carbonyl group. When used with glucose strips, the esters discerned clinically relevant levels of LE up to at least 26 nM (800 μg L) in the microliter-sized samples of bodily fluids. The reading of glucose strips with a potentiostat, instead of a personal glucose meter (blood glucometer), shortened the time of required sample incubation from 3 h to 5 min. Correcting the signal of incubated sample for that of original sample eliminated matrix effects and accounted for the presence of native glucose. The new esters have a potential to extend the use of glucose strips (already used by millions for diabetes monitoring) to the quantification of the severity of urinary tract and periprosthetic joint infections.

Citing Articles

Determination of glucose oxidase activity by tyrosine fluorescence spectrophotometry.

Zhang A, Zhang X, Yang L, He F, Dai X, Dong N Heliyon. 2024; 10(12):e32540.

PMID: 38975187 PMC: 11225733. DOI: 10.1016/j.heliyon.2024.e32540.


Self-Immolative Electrochemical Redox Substrates: Emerging Artificial Receptors in Sensing and Biosensing.

Manibalan K, Arul P, Wu H, Huang S, Mani V ACS Meas Sci Au. 2024; 4(2):163-183.

PMID: 38645581 PMC: 11027205. DOI: 10.1021/acsmeasuresciau.3c00057.


Leukocyte Esterase Strip Quantitative Detection Based on RGB Photometry is a Probable Method to Diagnose Periprosthetic Joint Infection: An Exploratory Study.

Zheng Q, Ren P, Cheng L, Liu H, Zhao R, Lv Y Orthop Surg. 2023; 15(4):983-992.

PMID: 36782275 PMC: 10102294. DOI: 10.1111/os.13667.


Diagnostic Accuracy for Periprosthetic Joint Infection Does Not Improve by a Combined Use of Glucose and Leukocyte Esterase Strip Reading as Diagnostic Parameters.

Haertle M, Kolbeck L, Macke C, Graulich T, Stauss R, Omar M J Clin Med. 2022; 11(11).

PMID: 35683369 PMC: 9181009. DOI: 10.3390/jcm11112979.


Application of leukocyte esterase strip test in the screening of periprosthetic joint infections and prospects of high-precision strips.

Zheng Q, Zhang G Arthroplasty. 2022; 2(1):34.

PMID: 35236471 PMC: 8796411. DOI: 10.1186/s42836-020-00053-5.