» Articles » PMID: 3189709

Radioimmunoguided Surgery Using Monoclonal Antibody

Overview
Journal Am J Surg
Specialty General Surgery
Date 1988 Nov 1
PMID 3189709
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

The potential proficiency of radioimmunoguided surgery in the intraoperative detection of tumors was assessed using labeled monoclonal antibody B72.3 in 66 patients with tissue-proved tumor. Monoclonal antibody B72.3 was injected 5 to 42 days preoperatively, and the hand-held gamma-detecting probe was used intraoperatively to detect the presence of tumor. Intraoperative probe counts of less than 20 every 2 seconds, or tumor-to-adjacent normal tissue ratios less than 2:1 were considered negative (system failure). Positive probe counts were detected in 5 of 6 patients with primary colon cancer (83 percent), in 31 of 39 patients with recurrent colon cancer (79 percent), in 4 of 5 patients with gastric cancer (80 percent), in 3 of 8 patients with breast cancer (37.5 percent), and in 4 of 8 patients with ovarian cancer (50 percent) undergoing second-look procedures. Additional patients in each group were scored as borderline positive. Overall, radioimmunoguided surgery using B72.3 identified tumors in 47 patients (71.2 percent), bordered on positive in 6 patients (9.1 percent), and failed to identify tumor in 13 patients (19.7 percent). Improved selection of patients for antigen-positive tumors, the use of higher affinity second-generation antibodies, alternate routes of antibody administration, alternate radionuclides, and more sophisticatedly bioengineered antibodies and antibody combinations should all lead to improvements in radioimmunoguided surgery.

Citing Articles

Evaluation of two intraoperative gamma detectors for assessment of Lu activity concentration in vivo.

Sandblom V, Stahl I, Olofsson Bagge R, Forssell-Aronsson E EJNMMI Phys. 2017; 4(1):3.

PMID: 28070731 PMC: 5222763. DOI: 10.1186/s40658-016-0168-x.


Site specific discrete PEGylation of (124)I-labeled mCC49 Fab' fragments improves tumor MicroPET/CT imaging in mice.

Ding H, Carlton M, Povoski S, Milum K, Kumar K, Kothandaraman S Bioconjug Chem. 2013; 24(11):1945-54.

PMID: 24175669 PMC: 4240220. DOI: 10.1021/bc400375f.


124I-HuCC49deltaCH2 for TAG-72 antigen-directed positron emission tomography (PET) imaging of LS174T colon adenocarcinoma tumor implants in xenograft mice: preliminary results.

Zou P, Povoski S, Hall N, Carlton M, Hinkle G, Xu R World J Surg Oncol. 2010; 8:65.

PMID: 20691066 PMC: 2924340. DOI: 10.1186/1477-7819-8-65.


A comprehensive overview of radioguided surgery using gamma detection probe technology.

Povoski S, Neff R, Mojzisik C, OMalley D, Hinkle G, Hall N World J Surg Oncol. 2009; 7:11.

PMID: 19173715 PMC: 2653072. DOI: 10.1186/1477-7819-7-11.


Gamma probes and their use in tumor detection in colorectal cancer.

Sarikaya I, Sarikaya A, Reba R Int Semin Surg Oncol. 2008; 5:25.

PMID: 19019238 PMC: 2596150. DOI: 10.1186/1477-7800-5-25.