» Articles » PMID: 31890765

Understanding the Formation and Behaviors of Droplets Toward Consideration of Changeover During Cell Manufacturing

Overview
Journal Regen Ther
Date 2020 Jan 1
PMID 31890765
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Preventing the contamination of processed cells is required for achieving reproducible manufacturing. A droplet is one of the potential causes contamination in cell manufacturing. The present study elucidates the formation mechanism and characteristics of droplets based on the observation and detection of droplets on the base surface of the biological safety cabinet (BSC) where cell processing is conducted under unidirectional airflow. Pouring fluorescent solution into the vessel using a measuring pipette was conducted to visualize the formation of droplets by videos as well as visual detection by blacklight irradiation on the base surface of the BSC. The experiments revealed that airborne and non-airborne droplets emerged from bursting bubbles, which formed when the entire solution was pushed out of the measuring pipette. Therefore, the improving procedure of pouring technique when entire solution was not pushed out of the pipette realized no formation of the droplets due to the prevention of emergence of bubble. In addition, an alternative procedure in which the entire solution was poured into the deep point of the test tube prevented the flying of non-airborne droplets outside the tube, while airborne droplets that escaped the tube rode the airflow of BSC. These results suggested a method for the prevention of the droplet formation, as well as the deposit control of droplets onto the surface in BSC, leading to cleanup area in the BSC for changeover with environment continuity.

Citing Articles

Changeover method for biosafety cabinets using ozone gas.

Mizuno M, Suda D, Matsumura C, Sekiya I PLoS One. 2025; 20(1):e0318006.

PMID: 39874382 PMC: 11774351. DOI: 10.1371/journal.pone.0318006.


Cleaning methods for biosafety cabinet to eliminate residual mycoplasmas, viruses, and endotoxins after changeover.

Mizuno M, Kimbara S, Ichise H, Ishikawa N, Nishihara Y, Nishio M Regen Ther. 2024; 28:73-80.

PMID: 39703815 PMC: 11655690. DOI: 10.1016/j.reth.2024.11.020.


Approach of design for air mass balance in an aseptic processing area for cell-based products.

Furomitsu S, Mizutani M, Kino-Oka M Regen Ther. 2024; 28:20-29.

PMID: 39664364 PMC: 11629579. DOI: 10.1016/j.reth.2024.11.009.


Decreasing electricity costs of clean room for cell products during non-operation.

Mizuno M, Abe K, Kakimoto T, Hasebe H, Sekiya I Regen Ther. 2024; 26:1117-1123.

PMID: 39635580 PMC: 11614862. DOI: 10.1016/j.reth.2024.11.002.


Evaluation of cleaning methods for change-over after the processing of cell products to avoid cross-contamination risk.

Mizuno M, Yori K, Takeuchi T, Yamamoto T, Ishikawa N, Kobayashi M Regen Ther. 2024; 26:489-495.

PMID: 39131505 PMC: 11315063. DOI: 10.1016/j.reth.2024.07.002.


References
1.
Xie X, Li Y, Chwang A, Ho P, Seto W . How far droplets can move in indoor environments--revisiting the Wells evaporation-falling curve. Indoor Air. 2007; 17(3):211-25. DOI: 10.1111/j.1600-0668.2007.00469.x. View

2.
Boyce J . Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals. Antimicrob Resist Infect Control. 2016; 5:10. PMC: 4827199. DOI: 10.1186/s13756-016-0111-x. View

3.
KRUSE R, Puckett W, Richardson J . Biological safety cabinetry. Clin Microbiol Rev. 1991; 4(2):207-41. PMC: 358192. DOI: 10.1128/CMR.4.2.207. View

4.
Jones R, Brosseau L . Aerosol transmission of infectious disease. J Occup Environ Med. 2015; 57(5):501-8. DOI: 10.1097/JOM.0000000000000448. View

5.
Houkin K, Shichinohe H, Abe K, Arato T, Dezawa M, Honmou O . Accelerating Cell Therapy for Stroke in Japan: Regulatory Framework and Guidelines on Development of Cell-Based Products. Stroke. 2018; 49(4):e145-e152. DOI: 10.1161/STROKEAHA.117.019216. View