» Articles » PMID: 31787777

Mechanical Stimulation of Growth Plate Chondrocytes: Previous Approaches and Future Directions

Overview
Journal Exp Mech
Date 2019 Dec 3
PMID 31787777
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

Growth plate cartilage resides near the ends of long bones and is the primary driver of skeletal growth. During growth, both intrinsically and extrinsically generated mechanical stresses act on chondrocytes in the growth plate. Although the role of mechanical stresses in promoting tissue growth and homeostasis has been strongly demonstrated in articular cartilage of the major skeletal joints, effects of stresses on growth plate cartilage and bone growth are not as well established. Here, we review the literature on mechanobiology in growth plate cartilage at macroscopic and microscopic scales, with particular emphasis on comparison of results obtained using different methodological approaches, as well as from whole animal and experiments. To answer these questions, macroscopic mechanical stimulators have been developed and applied to study mechanobiology of growth plate cartilage and chondrocytes. However, the previous approaches have tested a limited number of stress conditions, and the mechanobiology of a single chondrocyte has not been well studied due to limitations of the macroscopic mechanical stimulators. We explore how microfluidics devices can overcome these limitations and improve current understanding of growth plate chondrocyte mechanobiology. In particular, microfluidic devices can generate multiple stress conditions in a single platform and enable real-time monitoring of metabolism and cellular behavior using optical microscopy. Systematic characterization of the chondrocytes using microfluidics will enhance our understanding of how to use mechanical stresses to control the bone growth and the properties of tissue-engineered growth plate cartilage.

Citing Articles

Hand skeletal features of children and adolescents with different growth statuses and periods.

Cao L, Liu C, Wu T, Shi L, Wen J, Guo Z Quant Imaging Med Surg. 2024; 14(3):2528-2538.

PMID: 38545069 PMC: 10963808. DOI: 10.21037/qims-23-26.


Homeostatic Regulation of Pro-Angiogenic and Anti-Angiogenic Proteins via Hedgehog, Notch Grid, and Ephrin Signaling in Tibial Dyschondroplasia.

Nawaz S, Kulyar M, Mo Q, Yao W, Iqbal M, Li J Animals (Basel). 2023; 13(24).

PMID: 38136788 PMC: 10740744. DOI: 10.3390/ani13243750.


Mucopolysaccharidosis IVA: Current Disease Models and Drawbacks.

Leal A, Almeciga-Diaz C, Tomatsu S Int J Mol Sci. 2023; 24(22).

PMID: 38003337 PMC: 10671113. DOI: 10.3390/ijms242216148.


Mechanical loading due to muscle movement regulates establishment of the collagen network in the developing murine skeleton.

Ahmed S, Rogers A, Nowlan N R Soc Open Sci. 2023; 10(10):231023.

PMID: 37859832 PMC: 10582611. DOI: 10.1098/rsos.231023.


Novel dual: rod plate system for EOS improves vertebral wedging and permits spinal growth.

Zheng Y, Zhou J, Niu C, Ye Q, Tang J, Wang X J Orthop Surg Res. 2023; 18(1):738.

PMID: 37773144 PMC: 10540359. DOI: 10.1186/s13018-023-04094-9.


References
1.
Sun K, Liu F, Wang J, Guo Z, Ji Z, Yao M . The effect of mechanical stretch stress on the differentiation and apoptosis of human growth plate chondrocytes. In Vitro Cell Dev Biol Anim. 2016; 53(2):141-148. DOI: 10.1007/s11626-016-0090-5. View

2.
Wang X, Mao J . Accelerated chondrogenesis of the rabbit cranial base growth plate by oscillatory mechanical stimuli. J Bone Miner Res. 2002; 17(10):1843-50. DOI: 10.1359/jbmr.2002.17.10.1843. View

3.
Akyuz E, Braun J, Brown N, Bachus K . Static versus dynamic loading in the mechanical modulation of vertebral growth. Spine (Phila Pa 1976). 2006; 31(25):E952-8. DOI: 10.1097/01.brs.0000248810.77151.22. View

4.
Lu H, Koo L, Wang W, Lauffenburger D, Griffith L, Jensen K . Microfluidic shear devices for quantitative analysis of cell adhesion. Anal Chem. 2004; 76(18):5257-64. DOI: 10.1021/ac049837t. View

5.
Draper E, Goodship A . A novel technique for four-point bending of small bone samples with semi-automatic analysis. J Biomech. 2003; 36(10):1497-502. DOI: 10.1016/s0021-9290(03)00129-5. View