» Articles » PMID: 17139211

Static Versus Dynamic Loading in the Mechanical Modulation of Vertebral Growth

Overview
Specialty Orthopedics
Date 2006 Dec 2
PMID 17139211
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

Study Design: Measures of absolute and relative growth modulation were used to determine the effects of static and dynamic asymmetric loading of vertebrae in the rat tail.

Objectives: To quantify the differences between static and dynamic asymmetric loading in vertebral bone growth modulation.

Summary Of Background Data: The creation and correction of vertebral wedge deformities have been previously described in a rat-tail model using static loading. The effects of dynamic loading on growth modulation in the spine have not been characterized.

Methods: A total of 36 immature Sprague-Dawley rats were divided among four different groups: static loading (n = 12, 0.0 Hz), dynamic loading (n = 12, 1.0 Hz), sham operated (n = 6), and growth controls (n = 6). An external fixator was placed across the sixth and eighth caudal vertebrae as the unviolated seventh caudal vertebra was evaluated for growth modulation. Static or dynamic asymmetric loads were applied at a loading magnitude of 55% body weight. After 3 weeks of loading, growth modulation was assessed using radiographic measurements of vertebral wedge angles and vertebral body heights.

Results: The dynamically loaded rats had a final average wedge deformity of 15.2+/- 6.4 degrees, which was significantly greater than the statically loaded rats whose final deformity averaged 10.3 degrees +/- 3.7 degrees (P < 0.03). The deformity in both groups was statistically greater than the sham-operated (1.1+/- 2.0 degrees) and growth control rats (0.0+/- 1.0 degrees) (P < 0.001). The longitudinal growth was significantly lower on the concavity compared with the convexity in both the dynamically (0.34 +/- 0.23 mm vs. 0.86 +/- 0.23 mm) and statically (0.46 +/- 0.19 mm vs. 0.83 +/- 0.32 mm) loaded rats (P < 0.001). These growth rates were significantly less than the sham operated and growth control rats (P < 0.001).

Conclusions: A variety of fusionless scoliosis implant strategies have been proposed that use both rigid and flexible implants to modulate vertebral bone growth. The results from this study demonstrate that dynamic loading of the vertebrae provides the greatest growth modulation potential.

Citing Articles

Biomechanical behavior of titanium, cobalt-chromium, zirconia, and PEEK frameworks in implant-supported prostheses: a dynamic finite element analysis.

Sahin Hazir D, Sozen Yanik I, Guncu M, Canay R BMC Oral Health. 2025; 25(1):97.

PMID: 39827102 PMC: 11748589. DOI: 10.1186/s12903-025-05486-5.


Anterior vertebral tethering for adolescent idiopathic scoliosis: our initial ten year clinical experience.

Braun J, Federico S, Lawlor D, Paschos N, Croitoru D, Grottkau B Spine Deform. 2024; 12(5):1355-1367.

PMID: 38796815 PMC: 11344032. DOI: 10.1007/s43390-024-00897-w.


Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: a 3D finite element analysis.

Deste Gokay G, Oyar P, Gokcimen G, Durkan R BMC Oral Health. 2024; 24(1):545.

PMID: 38730391 PMC: 11088090. DOI: 10.1186/s12903-024-04328-0.


An investigation of range of motion preservation in fusionless anterior double screw and cord constructs for scoliosis correction.

Trobisch P, Mahoney J, Eichenlaub E, Antonacci C, Cuddihy L, Amin D Eur Spine J. 2023; 32(4):1173-1186.

PMID: 36871254 DOI: 10.1007/s00586-023-07608-5.


Short term outcomes and complications of distal ulnar ostectomy in 23 juvenile dogs with carpal valgus secondary to discordant radial-ulnar physeal growth.

Christopher S Front Vet Sci. 2022; 9:971527.

PMID: 36157189 PMC: 9501678. DOI: 10.3389/fvets.2022.971527.